Home >> Toyota >> 2012 >> Highlander Limited, FWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 115 (Hybrid Vehicle Control System (Diagnostic Codes (P0ADB-227 - U0424-537) & Circuit Tests)) (Hybrid)) >> Hybrid Control System >> DTC P0AE2-773: Hybrid Battery Precharge Contactor Circuit Stuck Closed >> Procedure

DTC P0AE2-773: Hybrid Battery Precharge Contactor Circuit Stuck Closed: Procedure

WARNING: This page is about a different variant/trim than selected.
  1. CHECK DTC OUTPUT (HV) 
    1. Connect the Techstream to the DLC3.
    2. Turn the ignition switch to ON.
    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
    4. Check if DTCs are output.

      Result

      Result Proceed to
      P0AE2-773 only is output. A
      Any of the following DTCs are also output. B
      DTC No. Relevant Diagnosis
      P0A1A-151, 155, 156, 200, 658, 659, 791, 792, 793 Generator Control Module
      P0A1B-163, 164, 168, 193, 511, 512, 661, 786, 794, 795, 796 Drive Motor "A" Control Module
      P0A1C-708, 709, 710, 715, 797, 798, 799 Drive Motor "B" Control Module
      P0A1D-148 Hybrid Powertrain Control Module
      P0A3F-243 Drive Motor "A" Position Sensor Circuit
      P0A40-500 Drive Motor "A" Position Sensor Circuit Range/Performance
      P0A41-245 Drive Motor "A" Position Sensor Circuit Low
      P0A45-669 Drive Motor "B" Position Sensor Circuit
      P0A46-671 Drive Motor "B" Position Sensor Circuit Range/Performance
      P0A47-670 Drive Motor "B" Position Sensor Circuit Low
      P0A4B-253 Generator Position Sensor Circuit
      P0A4C-513 Generator Position Sensor Circuit Range/Performance
      P0A4D-255 Generator Position Sensor Circuit Low
      P0A78-266, 267, 586 Drive Motor "A" Inverter Performance
      P0A91-702 Drive Motor "B" Performance
      P0A94-442 DC / DC Converter Performance
      P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High
      P0AA4-232 Hybrid Battery Negative Contactor Circuit Stuck Closed
      P0AE7-224 Hybrid Battery Precharge Contactor Control Circuit High
      P0C76-523 Hybrid Battery System Discharge Time Too Long
      P2511-149 HV CPU Power Relay Sense Circuit Intermittent No Continuity
      P3004-132 Power Cable Malfunction
      P310A-711 Communication Error from RMG to Motor
      P310B-662 Communication Error from Motor to RMG
      P324E-788 MG-ECU Power Relay Intermittent Circuit
      U0110 (all INF codes)*1 Lost Communication with Drive Motor Control Module "A"

      HINT: 

      • *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
      • P0AE2-773 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.
    5. Turn the ignition switch off.

    B → See step   6 

    A: Go to next step 

  2. CHECK FREEZE FRAME DATA 
    1. Connect the Techstream to the DLC3.
    2. Turn the ignition switch to ON.
    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
    4. Read the freeze frame data of DTC P0AE2-773.

      Result

      Result Proceed to
      Pre-boost voltage (VL) is less than 55 V. A
      Post-boost voltage (VL) is 55 V or more. B
    5. Turn the ignition switch off.

    A → See step   5 

    B: Go to next step 

  3. CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY 
    WARNING:

    Be sure to wear insulated gloves.

    1. Check that the service plug grip is not installed.
      NOTE:

      After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair information because this may cause a malfunction.

    2. Remove the battery cover sub-assembly. Refer to REMOVAL .
    3. Measure the resistance according to the value(s) in the table below.
      Fig 1: Identifying Hybrid Battery Junction Block Assembly
      GTY299239Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      Standard Resistance

      Tester Connection Switch Condition Specified Condition
      j3-1 - z31-1 Ignition switch off 10 kΩ or higher
      TEXT IN ILLUSTRATION

      *1 Hybrid Battery Junction Block Assembly

      HINT: 

      • If a system main relay is stuck closed, inspect the HV relay assembly without removing it from the vehicle in order to keep the relay closed.
      • If the result of reading the freeze frame data is B, the HV battery junction block must be replaced. Measuring resistance can determine that this is either a present or past malfunction.
    4. Install the battery cover sub-assembly. Refer to INSTALLATION .

    NG → See step   4 

    OK → See step   4 

  4. REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY. Refer to  REMOVAL 
  5. REPLACE INVERTER WITH CONVERTER ASSEMBLY. Refer to  REMOVAL 
  6. GO TO DTC CHART. Refer to  DIAGNOSTIC TROUBLE CODE CHART