Television Display Power Source Circuit: Procedure
- CHECK HARNESS AND CONNECTOR (TELEVISION DISPLAY ASSEMBLY - BATTERY, BODY GROUND)
- Disconnect the television display assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition Q13-12 (GND6) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester Connection Condition Specified Condition Q13-16 (+B2) - Body ground Always 11 to 14 V Q13-15 (ACC4) - Body ground Ignition switch on (ACC) 11 to 14 V
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 2
- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE