TC and CG Terminal Circuit: Procedure
- CHECK HARNESS AND CONNECTOR (DLC3 - HYBRID VEHICLE CONTROL ECU AND BODY GROUND)
- Disconnect the D72 ECU connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition D47-13 (TC) - D72-11 (TC) Always Below 1 Ω D47-13 (TC) or D72-11 (TC) - Body ground Always 10 kΩ or higher D47-4 (CG) - Body ground Always Below 1 Ω
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR OR EACH ECU
OK: Go to next step
- INSPECT DLC3 (TC VOLTAGE)
- Connect the D72 ECU connector.
- Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester Connection Condition Specified Condition D47-13 (TC) - D47-4 (CG) Ignition switch ON 11 to 14 V
NG → REPLACE HYBRID VEHICLE CONTROL ECU
OK → See step 3
- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE