Inspection Procedure
WARNING:
- Wear electrically insulated gloves and pull out the service plug grip before inspection as procedures may require disconnecting high-voltage connectors. Be sure to carry the removed service plug grip to prevent other technicians from accidentally reinstalling it.
- Do not touch the high-voltage connectors or terminals for 10 minutes after the service plug grip is removed.
- Verify that the voltage of the inverter with converter assembly is 0 V before working inside the inverter with converter assembly.
NOTE:
Depending on the timing of the power supply to the 12 V power supply circuit and high-voltage circuit when the ignition switch to ON (READY), an abnormal information signal may be output, causing this DTC to be stored. If the output DTC is a code that was memorized in the past, check the fuses and wire harnesses. If there is no malfunction, erase the DTC.