DTC B1462/62: Room Humidity Sensor Circuit: Procedure
- CHECK AIR CONDITIONING AMPLIFIER
- Remove the air conditioning amplifier with the connectors still connected. Refer to REMOVAL .
- Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester connection Condition Specified Condition D37-28 (RH) - D37-35 (SG-4) Ignition switch ON
at 25°C (77°F)1.8 to 2.2 V D37-28 (RH) - D37-35 (SG-4) Ignition switch ON
at 40°C (104°F)1.2 to 1.6 V HINT:
As the temperature increases, the voltage decreases.
Result
Result Proceed to NG A OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE) B OK (When troubleshooting according to the DTC) C
B → See step 5
C → See step 6
A: Go to next step
- CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
- Disconnect the D26 sensor connector.
- Disconnect the D37 amplifier connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition D37-28 (RH) - D26-3 (RH) Always Below 1 Ω D37-31 (S5-4) - D26-4 (S5) Always Below 1 Ω D37-35 (SG-4) - D26-2 (-) Always Below 1 Ω D37-28 (RH) - Body ground Always 10 kΩ or higher D37-31 (S5-4) - Body ground Always 10 kΩ or higher D37-35 (SG-4) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
- Reconnect the D37 amplifier connector.
- Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester Connection Switch Condition Specified Condition D26-4 (S5) - Body ground Ignition switch ON 4.5 to 5.5 V - Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition D26-2 (-) - Body ground Always Below 1 Ω
NG → See step 6
OK: Go to next step
- INSPECT ROOM TEMPERATURE SENSOR (FRONT ROOM TEMPERATURE SENSOR)
- Remove the room temperature sensor with its connector still connected. Refer to REMOVAL .
- Turn the ignition switch to ON.
- Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester Connection Condition Specified Condition D26-3 (RH) - D26-2 (-) Humidity 10%
at 25°C (77°F)0.7 to 1.08 V D26-3 (RH) - D26-2 (-) Humidity 20%
at 25°C (77°F)0.72 to 1.57 V D26-3 (RH) - D26-2 (-) Humidity 30%
at 25°C (77°F)1.13 to 1.95 V D26-3 (RH) - D26-2 (-) Humidity 40%
at 25°C (77°F)1.61 to 2.24 V D26-3 (RH) - D26-2 (-) Humidity 650%
at 25°C (77°F)1.99 to 2.46 V D26-3 (RH) - D26-2 (-) Humidity 60%
at 25°C (77°F)2.26 to 2.66 V D26-3 (RH) - D26-2 (-) Humidity 70%
at 25°C (77°F)2.48 to 2.85 V D26-3 (RH) - D26-2 (-) Humidity 80%
at 25°C (77°F)2.68 to 3.04 V D26-3 (RH) - D26-2 (-) Humidity 90%
at 25°C (77°F)2.87 to 3.05 V NOTE:- Touching the sensor even slightly may change the output voltage. Be sure to hold the connector of the sensor.
- The output voltages shown above are at 25°C (77°F).
NG → See step 7
OK → See step 6
- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE
- REPLACE AIR CONDITIONING AMPLIFIER. Refer to REMOVAL
- REPLACE ROOM TEMPERATURE SENSOR (FRONT ROOM TEMPERATURE SENSOR). Refer to REMOVAL