DTC B1423/23: Pressure Sensor Circuit: Description
This DTC is output if refrigerant pressure on the high pressure side is extremely low (0.176 MPa (2.0 kgf/cm2 , 28 psi) or less) or extremely high (3.03 MPa (32.0 kgf/cm2 , 440 psi) or more). The pressure sensor, which is installed on the pipe on the high pressure side to detect refrigerant pressure, outputs a refrigerant pressure signal to the air conditioning amplifier. The air conditioning amplifier converts this signal to a pressure value according to the sensor characteristics, to control the compressor.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1423/23 |
|
|