Home >> Toyota >> 2012 >> Highlander Hybrid >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 127 (Air Conditioning (Manual) (Diagnostic Codes & Circuit Tests) (Except Hybrid)) >> AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) >> DTC B1413/13: Evaporator Temperature Sensor Circuit >> Description

DTC B1413/13: Evaporator Temperature Sensor Circuit: Description

WARNING: This page is about a different variant/trim than selected.

The No. 1 cooler thermistor (evaporator temperature sensor) is installed on the evaporator in the air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and to control the air conditioner. It sends signals to the air conditioning amplifier. The signals change in accordance with the resistance of the No. 1 cooler thermistor (evaporator temperature sensor). As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases. The air conditioning amplifier applies a voltage (5 V) to the No. 1 cooler thermistor (evaporator temperature sensor) and reads voltage changes as changes in the resistance of the No. 1 cooler thermistor (evaporator temperature sensor). This sensor is used for frost prevention.

DTC No. DTC Detection Condition Trouble Area
B1413/13 Open or short in evaporator temperature sensor circuit
  • No. 1 cooler thermistor (evaporator temperature sensor)
  • Wire harness between No. 1 cooler thermistor (evaporator temperature sensor) and air conditioning amplifier
  • Air conditioning amplifier