Power Source Circuit: Procedure
- CHECK HARNESS AND CONNECTOR
- Disconnect the E11 meter connector.
- Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester Connection Condition Specified Condition E11-6 (+B) - Body ground Always 11 to 14 V E11-1 (IG) - Body ground Ignition switch ON 11 to 14 V - Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition E11-5 (GND) - Body ground Always Below 1 Ω
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 2