Sliding Roof does not Move by Operating Sliding Roof Control Switch: Procedure
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Sliding Roof / Data List.
- Read the Data List according to the display on the Techstream.SLIDING ROOF (SLIDING ROOF ECU (SLIDING ROOF DRIVE GEAR SUB-ASSEMBLY))
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Open Switch OPEN switch signal/ON or OFF ON: OPEN switch pressed
OFF: OPEN switch not pressed- Close Switch CLOSE switch signal/ON or OFF ON: CLOSE switch pressed
OFF: CLOSE switch not pressed- Up Switch UP switch signal/ON or OFF ON: UP switch pressed
OFF: UP switch not pressed- Down Switch DOWN switch signal/ON or OFF ON: DOWN switch pressed
OFF: DOWN switch not pressed- OK
The Techstream display changes according to switch operation as shown in the table.
NG → See step 3
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (SLIDING ROOF ECU - BATTERY AND BODY GROUND)
- Disconnect the S4 sliding roof ECU (sliding roof drive gear sub-assembly) connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition S4-8 (B) - Body ground Always 11 to 14 V - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition S4-12 (E) - Body ground Always Below 1 Ω
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 5
- INSPECT SLIDING ROOF SWITCH (ROOF CONSOLE BOX ASSEMBLY)
- Remove the sliding roof switch (roof console box assembly). Refer to REMOVAL .
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 5 (UP) - 1 (GND) UP switch is pressed Below 1 Ω 5 (UP) - 1 (GND) UP switch is not pressed 10 kΩ or higher 4 (DOWN) - 1 (GND) DOWN switch is pressed Below 1 Ω 4 (DOWN) - 1 (GND) DOWN switch is not pressed 10 kΩ or higher 3 (OPN) - 1 (GND) OPEN switch is pressed Below 1 Ω 3 (OPN) - 1 (GND) OPEN switch is not pressed 10 kΩ or higher 2 (CLS) - 1 (GND) CLOSE switch is pressed Below 1 Ω 2 (CLS) - 1 (GND) CLOSE switch is not pressed 10 kΩ or higher TEXT IN ILLUSTRATION*a Component without harness connected
(Sliding Roof Switch (Roof Console Box Assembly))
NG → See step 6
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (SLIDING ROOF ECU - SLIDING ROOF SWITCH AND BODY GROUND)
- Disconnect the S12 sliding roof switch (roof console box assembly) connector.
- Disconnect the S4 sliding roof ECU (sliding roof drive gear sub-assembly) connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition S4-5 (CLS) - S12-2 (CLS) Always Below 1 Ω S4-5 (CLS) - Body ground Always 10 kΩ or higher S4-7 (OPN) - S12-3 (OPN) Always Below 1 Ω S4-7 (OPN) - Body ground Always 10 kΩ or higher S4-6 (DWN) - S12-4 (DOWN) Always Below 1 Ω S4-6 (DWN) - Body ground Always 10 kΩ or higher S4-4 (UP) - S12-5 (UP) Always Below 1 Ω S4-4 (UP) - Body ground Always 10 kΩ or higher S12-1 (GND) - Body ground Always Below 1 Ω S4-12 (E) - Body ground Always Below 1 Ω
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 5
- REPLACE SLIDING ROOF ECU (SLIDING ROOF DRIVE GEAR SUB-ASSEMBLY). Refer to REMOVAL .
- REPLACE SLIDING ROOF SWITCH (ROOF CONSOLE BOX ASSEMBLY). Refer to REMOVAL .