Monitor Description
WARNING: This page is about a different variant/trim than selected.
The battery smart unit, which monitors the voltage of the battery blocks, determines that malfunction has occurred if a voltage difference between the battery blocks exceeds the standard. When the malfunction detection condition is satisfied, the power management control ECU will illuminates the MIL and set a DTC.