Trip Switch: Inspection: Inspection
- INSPECT TRIP SWITCH
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1 (CS) - 12 (E) Unit change switch not pressed 10 kΩ or higher 1 (CS) - 12 (E) Unit change switch pressed Below 1 Ω 9 (HOUR) - 12 (E) Hour adjust switch not pressed 10 kΩ or higher 9 (HOUR) - 12 (E) Hour adjust switch pressed Below 1 Ω 10 (MIN) - 12 (E) Minute adjust switch not pressed 10 kΩ or higher 10 (MIN) - 12 (E) Minute adjust switch pressed Below 1 Ω 11 (RST) - 12 (E) Set switch not pressed 10 kΩ or higher 1 (RST) - 12 (E) Set switch pressed Below 1 Ω - Apply battery voltage from the wire harness back side between the terminals of the switch, and check the lighting condition of the trip switch.
OK
Measurement Condition Condition Specified Condition Battery positive (+) → 5 (ILL+)
Battery negative (-) → 4 (ILL-)Always Trip switch illuminates If the result is not as specified, replace the trip switch. Refer to REMOVAL .
- Measure the resistance according to the value(s) in the table below.