Meter Illumination is Always Dark: Procedure
- CHECK CAN COMMUNICATION SYSTEM
- Check for DTCs, refer to PRECAUTION
.RESULT
Result Proceed to DTC is not output A CAN communication system DTC is output B Lighting system DTC (B1244) is output C
B → See step 5
C → See step 6
A: Go to next step
- Check for DTCs, refer to PRECAUTION
.
- PERFORM ACTIVE TEST USING TECHSTREAM (DIMMER SWITCH)
- Operate the Techstream according to the display and select Active Test.MAIN BODY
Tester Display Test Part Control Range Diagnostic Note Dimmer Signal Illumination dimming operation ON or OFF - OK
Meter illumination is dimmed when the dimmer switch is ON.
HINT:
Refer to the sensitivity setting in the customization table of the automatic light control system, refer to CUSTOMIZE PARAMETERS .
NG → See step 3
OK → See step 7
- Operate the Techstream according to the display and select Active Test.
- REPLACE COMBINATION METER ASSEMBLY
- Temporarily replace the combination meter with a new one, refer to REMOVAL .
NEXT: Go to next step
- CHECK COMBINATION METER ASSEMBLY
- Check that the operation of the combination meter returns to normal, refer to OPERATION CHECK
.
OK
Operation of combination meter returns to normal.
NG → REPLACE MAIN BODY ECU (COWL SIDE JUNCTION BLOCK LH)
OK → END (COMBINATION METER IS DEFECTIVE)
- Check that the operation of the combination meter returns to normal, refer to OPERATION CHECK
.
- Go to CAN COMMUNICATION SYSTEM. Refer to PRECAUTION
- Go to LIGHTING SYSTEM. Refer to PRECAUTION
- CHECK LIGHTING SETTING. Refer to PRECAUTION