DTC B1500: Fuel Sender Open Detected: Procedure
- READ VALUE USING TECHSTREAM (FUEL SENDER GAUGE)
- Operate the Techstream according to the display and select the Data List, refer to DATA LIST / ACTIVE TEST
.COMBINATION METER
Tester Display Measurement Item/Range Normal Condition Diagnostic Note Fuel Input Fuel sender gauge (main) input signal/Min.: 0, Max.: 127.5 Fuel sender input value Unit: L OK
Fuel value displayed on the Techstream is almost the same as needle indication.
NG → See step 2
OK → See step 5
- Operate the Techstream according to the display and select the Data List, refer to DATA LIST / ACTIVE TEST
.
- CHECK HARNESS AND CONNECTOR (COMBINATION METER - PUMP AND GAUGE AND BODY GROUND)
- Disconnect the E7 and E8 combination meter assembly connectors.
- Disconnect the N1 fuel suction with pump and gauge tube assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition E8-9 (L) - N1-2 (FS) Always Below 1 Ω E8-21 (E) - N1-3 (FE) Always Below 1 Ω E7-15 (ET) - Body ground Always Below 1 Ω E8-9 (L) or N1-2 (FS) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- INSPECT FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY
- Remove the fuel sender gauge assembly, refer to REMOVAL .
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition A-2 (FS) - B-2 (FS) Always Below 1 Ω A-3 (FE) - B-1 (FE) Always Below 1 Ω TEXT IN ILLUSTRATION*1 Component without harness connected
(Fuel Suction with Pump and Gauge Tube Assembly)*2 Connector A *3 Connector B
NG → See step 6
OK: Go to next step
- INSPECT FUEL SENDER GAUGE ASSEMBLY
- Remove the fuel sender gauge assembly, refer to REMOVAL .
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 2 (FS) - 1 (FE) Float level is F (upper) 13.5 to 16.5 Ω Float level is E (lower) 405.5 to 414.5 Ω TEXT IN ILLUSTRATION*1 Component without harness connected
(Fuel Sender Gauge Assembly)
NG → See step 7
OK → See step 8
- REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL
- REPLACE FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY. Refer to REMOVAL
- REPLACE FUEL SENDER GAUGE ASSEMBLY. Refer to REMOVAL
- REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL