IG Power Source Circuit: Procedure
- INSPECT FUSE (A/C NO. 2)
- Remove the A/C No. 2 fuse from the instrument panel junction block.
- Measure the resistance of the fuse.
Standard resistance
Tester Connection Condition Specified Condition A/C NO. 2 fuse Always Below 1 Ω
NG → REPLACE FUSE
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BATTERY)
- Install the A/C No. 2 fuse.
- Disconnect the D37 amplifier connector.
- Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester Connection Condition Specified Condition D37-1 (IG+) - Body ground Ignition switch ON 11 to 14 V
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BODY GROUND)
- Disconnect the D38 amplifier connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition D37-14 (GND) - Body ground Always Below 1 Ω D38-20 (GND2) - Body ground Always Below 1 Ω
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 4
- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE