Heater Control Panel Power Source Circuit: Procedure
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - BATTERY)
- Disconnect the E10 control connector.
- Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester Connection Switch Condition Specified Condition E10-2 (IG+) - Body ground Ignition switch ON 11 to 14 V E10-2 (IG+) - Body ground Ignition switch off Below 1 V
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - BODY GROUND)
- Measure the resistance according to the value(s) in the table below.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Standard resistance
Tester Connection Condition Specified Condition E10-10 (GND) - Body ground Always Below 1 Ω
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 3
- Measure the resistance according to the value(s) in the table below.
- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE