Home >> Toyota >> 2011 >> Highlander Hybrid >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning (Diagnostic Codes & Circuit Tests) (Hybrid) >> AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) >> DTC B1411/11: Room Temperature Sensor Circuit >> Procedure

DTC B1411/11: Room Temperature Sensor Circuit: Procedure

  1. INSPECT ROOM TEMPERATURE SENSOR 
    1. Remove the room temperature sensor (for front), refer to REMOVAL .
      Fig 1: Identifying Room Temperature Sensor
      GTY303163Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance

      Tester Connection Condition Specified Condition
      D26-1 (+) - D26-2 (-) 10°C (50°F) 3.00 to 3.73 kΩ
      D26-1 (+) - D26-2 (-) 15°C (59°F) 2.45 to 2.88 kΩ
      D26-1 (+) - D26-2 (-) 20°C (68°F) 1.95 to 2.30 kΩ
      D26-1 (+) - D26-2 (-) 25°C (77°F) 1.60 to 1.80 kΩ
      D26-1 (+) - D26-2 (-) 30°C (86°F) 1.28 to 1.47 kΩ
      D26-1 (+) - D26-2 (-) 35°C (95°F) 1.00 to 1.22 kΩ
      D26-1 (+) - D26-2 (-) 40°C (104°F) 0.80 to 1.00 kΩ
      D26-1 (+) - D26-2 (-) 45°C (113°F) 0.65 to 0.85 kΩ
      D26-1 (+) - D26-2 (-) 50°C (122°F) 0.50 to 0.70 kΩ
      D26-1 (+) - D26-2 (-) 55°C (131°F) 0.44 to 0.60 kΩ
      D26-1 (+) - D26-2 (-) 60°C (140°F) 0.36 to 0.50 kΩ
      NOTE:
      • Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
      • When measuring, the sensor temperature must be the same as the ambient temperature.

      HINT: 

      As the temperature increases, the resistance decreases (see the graph).

    NG → See step   4 

    OK: Go to next step 

  2. CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) 
    1. Disconnect the D26 sensor connector.
      Fig 2: Identifying Harness And Connector (Room Temperature Sensor-Air Conditioning Amplifier)
      GTY302132Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Disconnect the D37 amplifier connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance

      Tester Connection Condition Specified Condition
      D26-1 (+) - D37-29 (TR) Always Below 1 Ω
      D26-2 (-) - D37-35 (SG-4) Always Below 1 Ω
      D26-1 (+) - Body ground Always 1 MΩ or higher
      D26-2 (-) - Body ground Always 1 MΩ or higher

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK → See step   3 

  3. REPLACE AIR CONDITIONING AMPLIFIER. Refer to  REMOVAL 
  4. REPLACE ROOM TEMPERATURE SENSOR. Refer to  REMOVAL