Monitor Strategy
WARNING: This page is about a different variant/trim than selected.
| Related DTCs |
P0705: Park/Neutral Position Switch/Verify Switch Input |
| Required Sensors/Components |
Park/neutral position switch |
| Frequency of Operation |
Continuous |
| Duration |
Condition (A) and (B): 2 seconds Condition (C): 60 seconds |
| MIL Operation |
2 driving cycles |
| Sequence of Operation |
None |