LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2011 >> Highlander Hybrid Limited >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 47 (Air Conditioning System (Manual) (Diagnostics - Introduction)) >> AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) >> Problem Symptoms Table >> Problem Symptoms Table

Problem Symptoms Table

WARNING: This page is about a different variant/trim than selected.

HINT: 

AIR CONDITIONING SYSTEM

Symptom Suspected Area See
No functions of air conditioning control panel operate LIN communication line -
Air conditioning control Refer to Heater Control Panel Power Source Circuit
Air conditioning amplifier Refer to REMOVAL
No functions of air conditioning system operate A/C NO. 2 fuse -
Air conditioning control Refer to Heater Control Panel Power Source Circuit
Air conditioning amplifier Refer to REMOVAL
Wire harness or connector -
Airflow Control: No blower control (Blower motor does not operate) HTR fuse -
Blower motor circuit Refer to Blower Motor Circuit
Air conditioning amplifier Refer to REMOVAL
Air conditioning control Refer to Heater Control Panel Power Source Circuit
Wire harness or connector -
Airflow Control: No blower control (Blower motor does not change speed) Blower motor circuit Refer to Blower Motor Circuit
Air conditioning amplifier Refer to REMOVAL
Air conditioning control Refer to Heater Control Panel Power Source Circuit
Temperature Control: No cool air comes out Refrigerant volume Refer to REPLACEMENT
Refrigerant pressure Refer to REPLACEMENT
Air conditioning pressure sensor Refer to DTC B1423/23: Pressure Sensor Circuit
Air flow circuit Refer to DTC B1479/79: Flow Sensor Circuit
Air conditioning compressor magnetic clutch circuit Refer to Air Conditioning Compressor Magnetic Clutch Circuit
Compressor lock sensor circuit Refer to DTC B1422/22: Compressor Lock Sensor Circuit
Compressor solenoid circuit Refer to DTC B1451/51: Compressor Solenoid Circuit
Air mix damper control servo motor circuit Refer to DTC B1441/41: Air Mix Damper Control Servo Motor Circuit (Passenger Side)
Evaporator temperature sensor circuit Refer to DTC B1413/13: Evaporator Temperature Sensor Circuit
Ambient temperature sensor circuit Refer to DTC B1412/12: Ambient Temperature Sensor Circuit
Expansion valve -
Air conditioning amplifier Refer to REMOVAL
Air conditioning control Refer to Heater Control Panel Power Source Circuit
ECM (for 2GR-FE) Refer to HOW TO PROCEED WITH TROUBLESHOOTING
ECM (for 1AR-FE) Refer to HOW TO PROCEED WITH TROUBLESHOOTING
LIN communication line -
CAN communication system Refer to PROBLEM SYMPTOMS TABLE
Temperature Control: No warm air comes out Air mix damper control servo motor circuit Refer to DTC B1441/41: Air Mix Damper Control Servo Motor Circuit (Passenger Side)
Air conditioning harness -
Air conditioning amplifier Refer to REMOVAL
Air conditioning control Refer to Heater Control Panel Power Source Circuit
ECM (2GR-FE) Refer to HOW TO PROCEED WITH TROUBLESHOOTING
ECM (1AR-FE) Refer to HOW TO PROCEED WITH TROUBLESHOOTING
LIN communication line -
CAN communication system Refer to PROBLEM SYMPTOMS TABLE
Temperature Control: Output air is warmer or cooler than set temperature or response is slow Air inlet damper control servo motor circuit Refer to DTC B1442/42: Air Inlet Damper Control Servo Motor Circuit
Heater radiator -
Expansion valve -
Air conditioning amplifier Refer to REMOVAL
Air conditioning control Refer to Heater Control Panel Power Source Circuit
ECM (2GR-FE) Refer to HOW TO PROCEED WITH TROUBLESHOOTING
ECM (1AR-FE) Refer to HOW TO PROCEED WITH TROUBLESHOOTING
LIN communication line -
CAN communication system Refer to PROBLEM SYMPTOMS TABLE
Temperature Control: No temperature control (Only Max. cool or Max. warm) Air conditioning amplifier Refer to REMOVAL
Air conditioning control Refer to Heater Control Panel Power Source Circuit
LIN communication line -
No air inlet control Air inlet damper control servo motor circuit Refer to DTC B1442/42: Air Inlet Damper Control Servo Motor Circuit
evaporator temperature sensor circuit Refer to DTC B1413/13: Evaporator Temperature Sensor Circuit
Air conditioning amplifier Refer to REMOVAL
No air flow mode control Air outlet damper control servo motor circuit Refer to DTC B1443/43: Air Outlet Damper Control Servo Motor Circuit
Air conditioning amplifier Refer to REMOVAL
Engine idle up does not occur, or is continuous Air conditioning compressor magnetic clutch circuit Refer to Air Conditioning Compressor Magnetic Clutch Circuit
Compressor lock sensor circuit Refer to DTC B1422/22: Compressor Lock Sensor Circuit
Compressor solenoid circuit Refer to DTC B1451/51: Compressor Solenoid Circuit
Air conditioning control Refer to Heater Control Panel Power Source Circuit
LIN communication line -
Air conditioning amplifier -
ECM (for 2GR-FE) Refer to HOW TO PROCEED WITH TROUBLESHOOTING
ECM (for 1AR-FE) Refer to HOW TO PROCEED WITH TROUBLESHOOTING
A/C indicator blinking Compressor solenoid circuit Refer to DTC B1451/51: Compressor Solenoid Circuit
Air conditioning amplifier Refer to REMOVAL
Diagnostic trouble codes are not recorded. Set mode is cleared when ignition switch turned off Air conditioning amplifier Refer to REMOVAL
Back-up power source circuit Refer to Back-up Power Source Circuit
AIR CONDITIONING SYSTEM (FOR REAR)

Symptom Suspected Area See
No functions of rear Air Conditioning panel operate LIN communication line -
Rear air conditioning control Refer to Rear Air Conditioning Control Panel Circuit
Air conditioning amplifier Refer to REMOVAL
No functions of rear Air Conditioning system operate A/C NO. 2 fuse -
Rear air conditioning control Refer to Rear Air Conditioning Control Panel Circuit
Air conditioning amplifier Refer to REMOVAL
Wire harness or connector -
Airflow Control: No blower control (Blower motor does not operate) RR CLR fuse -
Rear blower motor circuit Refer to Rear Blower Motor Circuit
Air conditioning amplifier Refer to REMOVAL
Rear air conditioning control Refer to Rear Air Conditioning Control Panel Circuit
Wire harness or connector -
Airflow Control: No blower control (Blower motor does not change speed) Rear blower motor circuit Refer to Rear Blower Motor Circuit
Air conditioning amplifier Refer to REMOVAL
Rear air conditioning control Refer to Rear Air Conditioning Control Panel Circuit
Temperature Control: No cool air comes out Refrigerant volume Refer to ON-VEHICLE INSPECTION
Refrigerant pressure Refer to ON-VEHICLE INSPECTION
Air conditioning pressure sensor Refer to DTC B1423/23: Pressure Sensor Circuit
Compressor and magnetic clutch circuit Refer to Air Conditioning Compressor Magnetic Clutch Circuit
Rear air mix damper control servo motor circuit Refer to DTC B1447/47: Rear Air Mix Damper Control Servo Motor Circuit
Rear evaporator temperature sensor circuit Refer to DTC B1417/17: Rear Evaporator Temperature Sensor Circuit
Ambient temperature sensor circuit Refer to DTC B1412/12: Ambient Temperature Sensor Circuit
LIN communication line -
Rear air conditioning control Refer to Rear Air Conditioning Control Panel Circuit
Air conditioning amplifier Refer to REMOVAL
Temperature Control: No warm air comes out Rear air mix damper control servo motor circuit Refer to DTC B1447/47: Rear Air Mix Damper Control Servo Motor Circuit
Rear air conditioning harness -
Air conditioning amplifier Refer to REMOVAL
Rear air conditioning control Refer to Rear Air Conditioning Control Panel Circuit
LIN communication line -