Combination Meter ECU Communication Stop Mode: Procedure
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
- Disconnect the E1 combination meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition E1-40 (E2) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition E1-21 (B) - Body ground Always 11 to 14 V E1-22 (B2) - Body ground Always 11 to 14 V E1-1 (IG+) - Body ground Ignition switch ON 11 to 14 V TEXT IN ILLUSTRATION*a Rear view of wire harness connector
(to Combination Meter Assembly)
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 2