ECU Power Source Circuit: Procedure
- CHECK INSTRUMENT PANEL JUNCTION BLOCK (MAIN BODY ECU (POWER SOURCE)
- Disconnect the 1D junction block connector.
- Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester Connection Condition Specified Condition 1D-16 - Body ground Always 11 to 14 V
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK - BODY GROUND)
- Disconnect the 1F and 1M junction block connectors.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Condition Specified Condition 1F-10 - Body ground Always Below 1 Ω 1M-9 - Body ground Always Below 1 Ω
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 3
- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE