DTC P0724: Brake Switch "B" Circuit High: Procedure
- READ VALUE USING DATA LIST (STP SIGNAL)
HINT:
Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
NOTE:In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
- Turn the ignition switch off.
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Powertrain / ECT / Data List.
- According to the display on the Techstream, read the Data List.
Standard
Item Measurement Item/
Range (display)Normal Condition Stop Light Switch Stop light switch status/
ON or OFF- Brake pedal is depressed: ON
- Brake pedal is released: OFF
NOTE:In the table above, the conditions listed under "Normal Condition" are reference conditions. Do not depend solely on these reference conditions when deciding whether a part is faulty.
Result
Result Proceed to OK B NG A
B → See step 3
A: Go to next step
- INSPECT STOP LIGHT SWITCH ASSEMBLY
- Remove the stop light switch assembly.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 1 - 2 Pin not pushed Below 1 Ω 3 - 4 Pin pushed Below 1 Ω 1 - 2 Pin pushed 10 kΩ or higher 3 - 4 Pin not pushed 10 kΩ or higher
NG → REPLACE STOP LIGHT SWITCH ASSEMBLY
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (STOP LIGHT SWITCH ASSEMBLY - TCM)
- Install the stop light switch assembly.
- Connect the stop light switch connector.
- Disconnect the TCM connector.
- Measure the voltage according to the value(s) in the table below when the brake pedal is depressed and released.
Standard Voltage
Tester Connection Condition Specified Condition C63-12 (STP) - Body ground Brake pedal is depressed 7.5 to 14 V C63-12 (STP) - Body ground Brake pedal is released Below 1 V
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 4
- REPLACE TCM. Refer to REMOVAL