  1. INSPECT INTAKE AIR CONTROL VALVE 
    1. Inspection procedure when applying voltage between the terminals:
      Fig 1: Applying Battery Voltage Between Terminals
      GTY124481Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      1. Disconnect the connector from the intake air control valve.
      2. Apply battery voltage between terminals 1 (-) and 2 (+) of the intake air control valve. Check that a clicking sound is heard from the intake air control valve.

        If the result is not as specified, replace the intake air surge tank.

  2. INSPECT AIR CLEANER ASSEMBLY 
    1. Apply 26.6 kPa (200 mmHg, 7.9 in. Hg) of vacuum to the actuator. Check if the valve rotates open, as shown in the illustration.
      Fig 2: Applying Vacuum To Actuator
      GTY146481Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Apply vacuum for 1 minute. The actuator should continue to keep the valve open.

      If the result is not as specified, replace the air cleaner assembly.