Entire Combination Meter does not Operate: Procedure
- CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)
- Disconnect the E30 connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition E30-40 (E2) - Body ground Always Below 1 Ω E30-39 (ES) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition E30-1 (B2) - Body ground Always 11 to 14 V E30-21 (B) - Body ground Always 11 to 14 V E30-22 (IG+) - Body ground Ignition switch on (IG) 11 to 14 V
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → REPLACE COMBINATION METER ASSEMBLY