Terminals Of Ecu
- CHECK AIR CONDITIONING AMPLIFIER
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Measure the voltage of the connectors.
HINT:
Check from the rear of the connector while it is connected to the air conditioning amplifier.
AIR CONDITIONING AMPLIFIER CONNECTOR TERMINALS REFERENCE CHARTTester Connection Wiring Color Terminal Description Condition Specified Condition D37-1 (IG+) - D37-14 (GND) GR - W-B Power source (IG) Ignition switch on (IG) 11 to 14 V D37-2 (SOL+) - D37-14 (GND) L-W-B A/C compressor operation signal Engine idling Pulse generation (see waveform 1 b) Blower switch LO A/C switch ON D37-3 (PTC1) - Body ground (*1) P - Body ground PTC NO. 1 heater relay operation signal Engine idling Below 1 V→11 to 14 V Set temperature: MAX HOT Engine coolant temperature: Below 65°C (149°F) Ambient temperature: Below 10°C(50°F) Blower switch OFF → LO D37-4 (PTC3) - Body ground (*1) W - Body ground PTC NO. 3 heater relay operation signal Engine idling Below 1 V→11 to 14 V Set temperature: MAX HOT Engine coolant temperature: Below 65°C (149-F) Ambient temperature: Below 10°C(50°F) Blower switch OFF → LO D37-5 (TAM) - D37-14 (GND) B-W-B Ambient temperature sensor signal Ignition switch on (IG) 1.8 to 2.2 V Ambient temperature: 25°C (77°F) D37-8 (LOCK) - D37-14 (GND) V-W-B Air compressor lock sensor signal Engine idling Pulse generation (see waveform 5 f) A/C switch ON Blower switch LO D37-9 (PRE) - D37-13 (SG-2) R-SB Air conditioning pressure sensor signal Refrigerant pressure: Normal 0.76 to 4.74 V D37-9 (PRE) - D37-13 (SG-2) R-SB Air conditioning pressure sensor signal Refrigerant pressure: Abnormal (less than 0.196 MPa [2.0 kgf/cm2 , 28 psi]) 0.5 to 4.83 V D37-9 (PRE) - D37-13 (SG-2) R-SB Air conditioning pressure sensor signal Refrigerant pressure: Abnormal (more than 3.14 MPa [32 kgf/cm2 , 455 psi]) 4.74 V or higher D37-10 (S5-3) - D37-14 (GND) O-W-B Power supply for pressure sensor Ignition switch on (IG) 4.5 to 5.5 V D37-11 (CANH) - D37-14 (GND) LG - W-B Hi-level CAN bus line Ignition switch on (IG) Pulse generation (see waveform 3 d) D37-12 (CANL) - D37-14 (GND) W-W-B Lo-level CAN bus line Ignition switch on (IG) Pulse generation (see waveform 4 e) D37-13 (SG-2) - Body ground SB - Body ground Ground for pressure sensor Always Below 1 V D37-14 (GND) - Body ground W-B - Body ground Ground for main power supply Always Below 1 V D37-20 (MGC) - D37-14 (GND) V-W-B A/C compressor magnetic clutch operation signal Engine idling Below 1 V Blower switch LO A/C switch ON D37-21 (B) - D37-14 (GND) LG - W-B Power source (Back-up) Always 11 to 14 V D37-22 (PTC2) - Body ground (*1) G - Body ground PTC NO. 2 heater relay operation signal Engine idling Below 1V→ 11 to 14 V Set temperature: MAX HOT Engine coolant temperature: Below 65°C (149°F) Ambient temperature: Below 10°C (50°F) Blower switch OFF → LO D37-23 (BLW) - D37-14 (GND) R-W-B Blower motor control signal Ignition switch on (IG) Pulse generation (see waveform 2 c) Blower switch LO D37-25 (ALT) - Body ground (*1) SB - Body ground Generator signal Engine idling Pulse generation D37-37 (LIN1) - D37-14 (GND) R-W-B LIN communication signal Ignition switch on (IG) Pulse generation D37-38 (RDEF) - D37-14 (GND) W-W-B Rear defogger switch signal Ignition switch on (IG) Rear defogger switch OFF 11 to 14 V D37-38 (RDEF) - D37-14 (GND) W-W-B Rear defogger switch signal Ignition switch on (IG) Rear defogger switch ON Below 1 V Z17-2 (BUS G) - Body ground - Ground for BUS IC Always Below 1 V z17-3 (BUS) - z17-2 (BUS G) - BUS IC control signal Ignition switch on (IG) Pulse generation z17-4 (BBUS) - z17-2 (BUS G) - Power supply for BUS IC Ignition switch on (IG) 11 to 14 V z17-5 (SGA) - Body ground - Ground for evaporator temperature sensor Always Below 1 V z17-6 (TEA) - z17-5 (SGA) - Evaporator temperature sensor signal Ignition switch on (IG) 1.4 to 1.8 V Evaporator temperature: 15°C(59°F) - Using an oscilloscope, check waveform 1.
Compressor and pulley operation signal
WAVEFORM REFERENCE CHARTItem Content Tester Connection D37-2 (SOL+) - D37-14 (GND) Tool Setting 5 V/DIV., 500 μsec/DIV. Condition Engine idling, Blower switch LO, A/C switch ON - Using an oscilloscope, check waveform 2.
Blower motor control signal
WAVEFORM REFERENCE CHARTItem Content Tester Connection D37-23 (BLW) - D37-14 (GND) Tool Setting 1 V/DIV., 500 μsec./DIV. Condition Ignition switch on (IG), Blower switch LO HINT:
When the blower level is increased, the duty ratio changes accordingly.
- Using an oscilloscope, check waveform 3.
CAN communication signal
WAVEFORM REFERENCE CHARTItem Content Tester Connection D37-11 (CANH) - D37-14 (GND) Tool Setting 1 V/DIV, 10 μsec./DIV. Condition Ignition switch on (IG) HINT:
The waveform varies depending on the CAN communication signal.
- Using an oscilloscope, check waveform 4.
CAN communication signal
WAVEFORM REFERENCE CHARTItem Content Tester Connection D37-12 (CANL) - D37-14 (GND) Tool Setting 1 V/DIV., 10 μsec./DIV. Condition Ignition switch on (IG) HINT:
The waveform varies depending on the CAN communication signal.
- Using an oscilloscope, check waveform 5.
A/C compressor lock sensor signal
WAVEFORM REFERENCE CHARTItem Content Tester Connection D37-8 (LOCK) - D37-14 (GND) Tool Setting 200mV/DIV., 10 ms./DIV. Condition Engine is running
Blower switch: LO
A/C switch: ONHINT:
The waveform varies depending on the CAN communication signal.
*1: w/ PTC Heater
- Measure the voltage of the connectors.
- CHECK FRONT AIR CONDITIONING CONTROL
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Measure the voltage of the connectors.
FRONT AIR CONDITIONING CONTROL CONNECTOR TERMINALS REFERENCE CHARTTester Connection Wiring Color Terminal Description Condition Specified Condition E10-2 (IG+) - E10-10 (GND) V-GR Power source (IG) Ignition switch on (IG) 11 to 14 V E10-5 (LIN1) - E10-10 (GND) R-GR LIN communication signal LIN switch on (IG) Pulse generation E10-10 (GND) - Body ground GR - Body ground Ground for front air conditioning control Always Below 1 V