Purge Valve: Inspection
WARNING: This page is about a different variant/trim than selected.
- INSPECT NO. 1 VACUUM SWITCHING VALVE
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
STANDARD RESISTANCE CHARTTester Connection Condition Specified Condition 1-2 20°C (68°F) 23 to 26 Ω If the result is not as specified, replace the No. 1 vacuum switching valve.
- Check the operation of the No. 1 vacuum switching valve.
- Check that air does not flow from port F when air is applied to port E.
- Apply battery voltage to the connector, and check the VSV operation.
OK
MEASUREMENT CONDITION AND SPECIFIED CONDITIONMeasurement Condition Specified Condition Battery positive (+) → Terminal 1 Battery negative (-) → Terminal 2 Air flows from port E to port F If the result is not as specified, replace the No. 1 vacuum switching valve.