LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2009 >> Highlander Limited, FWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 18 (Engine Control System (1AR-FE) - DTC P0125 - P0500) >> DTC P0455 Evaporative Emission Control System Leak Detected (Gross Leak); DTC P0456 Evaporative Emission Control System Leak Detected (Very Small Leak) >> Monitor Description

Monitor Description

WARNING: This page is about a different variant/trim than selected.

5 hours* after the ignition switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:

*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.

OPERATION DESCRIPTION

Sequence Operation Description Duration
- ECM activation Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned off. -
A Atmospheric pressure measurement Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system not between 70 kPa-a and 110 kPa-a (525 mmHg-a and 825 mmHg-a), ECM cancels EVAP system monitor.
10 seconds
B First reference pressure measurement In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. 60 seconds
C EVAP system pressure measurement Vent valve turned ON (closed) to shut EVAP system.
Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured.
Write down measured value as it will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes(1)
D Purge VSV monitor Purge VSV opened and then EVAP system pressure measured by ECM.
Large increase indicates normality.
10 seconds
E Second reference pressure measurement After second reference pressure measurement, leak check performed by comparing first and second reference pressure.
If stabilized system pressure higher than second reference pressure, ECM determines that EVAP system leaking.
60 seconds
- Final check Atmospheric pressure measured and then monitoring result recorded by ECM. -
(1) If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.
Fig 1: EVAP Pressure Chart
G06023171Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  1. P0455: EVAP gross leak

    In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized system pressure is higher than [second reference pressure x 0.2] (near atmospheric pressure), the ECM determines that the EVAP system has a large leak, illuminates the MIL and stores the DTC (2 trip detection logic).

  2. P0456: EVAP very small leak

    In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. If the stabilized system pressure is between the second reference pressure and [second reference pressure x 0.2], the ECM determines that the EVAP system has a small leak, illuminates the MIL and stores the DTC (2 trip detection logic).

    Fig 2: EVAP Pressure Malfunction Chart - EVAP Very Small Leak
    G06111061Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002