DTC Summary
WARNING: This page is about a different variant/trim than selected.
DTC SUMMARY
| DTC No. | Monitoring Item | Malfunction Detection Condition | Trouble Area | Detection Timing | Detection Logic |
|---|---|---|---|---|---|
| P043E | Reference orifice clogged | P043E, P043F, P2401, P2402 and P2419 stored when one of following conditions met during key-off EVAP monitor:
|
|
While ignition switch off | 2 trip |
| P043F | Reference orifice high-flow | ||||
| P2401 | Leak detection pump stuck OFF | ||||
| P2402 | Leak detection pump stuck ON | ||||
| P2419 | Vent valve stuck closed |
HINT:
The reference orifice is located inside the canister pump module.