POWER STEERING SYSTEM (for 2AZ-FE): Calibration
- ROTATION ANGLE SENSOR INITIALIZATION AND TORQUE SENSOR ZERO POINT CALIBRATION NOTE: Clear the rotation angle sensor calibration value, initialize the rotation angle sensor, and calibrate the torque sensor zero point if any of the following has occurred:
- The power steering ECU has been replaced.
- The steering column assembly has been replaced.
- Steering effort differs between left and right.
- Inspection before calibration.
- Turn the ignition switch off.
- Connect the Techstream to the DLC3.
- Turn the ignition switch on (IG).
- Turn the Techstream on.
- Calibrate the power steering ECU. Enter the following menus: Chassis / EMPS / Data List.
- Check the values by referring to the table below.
Power Steering ECU
POWER STEERING ECU REFERENCE CHARTTester Display Measurement Item/Range Normal Condition Diagnostic Note IG Power Supply ECU power source voltage/
Min.: 0 V
Max.: 20.1531 V11 to 14 V Ignition switch on (IG)
Standard voltage:
11 to 14 V
NOTE: If the IG power supply voltage is 9 V or less, calibration cannot be performed. In this case, charge or replace the battery, and then perform calibration. - Rotation angle sensor calibration value clear, rotation angle sensor initialization, and torque sensor zero point calibration.
NOTE:- If DTC C1516 (Torque Sensor Zero Point Adjustment Incomplete) is stored, the torque sensor zero point cannot be calibrated. Clear the DTC before starting calibration.
- If DTC C1526 (Rotation Angle Sensor Initialization Incomplete) is stored, the rotation angle sensor cannot be initialized. Clear the DTC before starting initialization.
- Turn the ignition switch off.
- Connect the Techstream to the DLC3.
- Turn the ignition switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Chassis / EMPS / Utility / Torque Sensor Adjustment.
NOTE:- Set the steering wheel to the center point and align the front tires straight ahead.
- Do not turn the steering wheel sharply.
- Do not touch the steering wheel during the torque sensor zero point calibration (for 3 seconds).