  1. INSPECT SHIFT SOLENOID VALVE SL3 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve SL3.

    2. Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.

      OK: The solenoid valve makes an operating sound. 

      If the result is not as specified, replace the shift solenoid valve SL3.

      Fig 1: Inspecting Shift Solenoid Valve SL3
      G06011464Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. INSPECT SHIFT SOLENOID VALVE SLT 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve SLT.

    2. Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.

      OK: The solenoid valve makes an operating sound. 

      If the result is not as specified, replace the shift solenoid valve SLT.

      Fig 2: Inspecting Shift Solenoid Valve SLT
      G06011465Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  3. INSPECT SHIFT SOLENOID VALVE S4 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Condition Specified Condition
      Solenoid Connector (S4) - Solenoid Body (S4) 20°C (68°F) 11 to 15 Ω

      If the value is not as specified, replace the shift solenoid valve S4.

    2. Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body, then check the operation of the valve.
      Fig 3: Inspecting Shift Solenoid Valve S4
      G06011466Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      OK: The solenoid valve makes an operating sound. 

      If the result is not as specified, replace the shift solenoid valve S4.

  4. INSPECT SHIFT SOLENOID VALVE SR 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Condition Specified Condition
      Solenoid Connector (SR) - Solenoid Body (SR) 20°C (68°F) 11 to 15 Ω

      If the value is not as specified, replace the shift solenoid valve SR.

    2. Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body, then check the operation of the valve.
      Fig 4: Inspecting Shift Solenoid Valve SR
      G06011467Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      OK: The solenoid valve makes an operating sound. 

      If the result is not as specified, replace the shift solenoid valve SR.

  5. INSPECT SHIFT SOLENOID VALVE DSL 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Condition Specified Condition
      Solenoid Connector (DSL) - Solenoid Body (DSL) 20°C (68°F) 11 to 13 Ω

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body DSL, then check the operation of the valve.

      OK: The solenoid valve makes an operating sound. 

      If the result is not as specified, replace the shift solenoid valve DSL.

      Fig 5: Inspecting Shift Solenoid Valve DSL
      G06011468Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  6. INSPECT SHIFT SOLENOID VALVE SL2 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve SL2.

    2. Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.

      OK: The solenoid valve makes an operating sound. 

      If the result is not as specified, replace the shift solenoid valve SL2.

      Fig 6: Inspecting Shift Solenoid Valve SL2
      G06011469Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  7. INSPECT SHIFT SOLENOID VALVE SL1 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve SL1.

    2. Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.

      OK: The solenoid valve makes an operating sound. 

      If the result is not as specified, replace the shift solenoid valve SL1.

      Fig 7: Inspecting Shift Solenoid Valve SL1
      G06011470Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002