Valve Body Assembly: Inspection
- INSPECT SHIFT SOLENOID VALVE SL3
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω If the value is not as specified, replace the shift solenoid valve SL3.
- Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.
OK: The solenoid valve makes an operating sound.
If the result is not as specified, replace the shift solenoid valve SL3.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SLT
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω If the value is not as specified, replace the shift solenoid valve SLT.
- Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.
OK: The solenoid valve makes an operating sound.
If the result is not as specified, replace the shift solenoid valve SLT.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE S4
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition Solenoid Connector (S4) - Solenoid Body (S4) 20°C (68°F) 11 to 15 Ω If the value is not as specified, replace the shift solenoid valve S4.
- Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body, then check the operation of the valve.
OK: The solenoid valve makes an operating sound.
If the result is not as specified, replace the shift solenoid valve S4.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SR
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition Solenoid Connector (SR) - Solenoid Body (SR) 20°C (68°F) 11 to 15 Ω If the value is not as specified, replace the shift solenoid valve SR.
- Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body, then check the operation of the valve.
OK: The solenoid valve makes an operating sound.
If the result is not as specified, replace the shift solenoid valve SR.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE DSL
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition Solenoid Connector (DSL) - Solenoid Body (DSL) 20°C (68°F) 11 to 13 Ω If the value is not as specified, replace the shift solenoid valve.
- Connect a positive (+) battery lead to the terminal of the solenoid connector, and a negative (-) battery lead to the solenoid body DSL, then check the operation of the valve.
OK: The solenoid valve makes an operating sound.
If the result is not as specified, replace the shift solenoid valve DSL.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SL2
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω If the value is not as specified, replace the shift solenoid valve SL2.
- Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.
OK: The solenoid valve makes an operating sound.
If the result is not as specified, replace the shift solenoid valve SL2.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SHIFT SOLENOID VALVE SL1
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω If the value is not as specified, replace the shift solenoid valve SL1.
- Connect a positive (+) battery lead with a 21 W bulb to terminal 2 and a negative (-) battery lead to terminal 1 of the solenoid valve connector, then check the operation of the valve.
OK: The solenoid valve makes an operating sound.
If the result is not as specified, replace the shift solenoid valve SL1.
- Measure the resistance according to the value(s) in the table below.