Transmission Wire: Inspection
WARNING: This page is about a different variant/trim than selected.
- INSPECT TRANSMISSION WIRE
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
RESISTANCE SPECIFICATIONTester Connection ATF Temperature Specified Condition 1 (THO) - 7 (E2) 10°C (50°F) 5 to 8 kΩ 1 (THO) - 7 (E2) 25°C (77°F) 2.5 to 4.5 kΩ 1 (THO) - 7 (E2) 110°C (230°F) 0.22 to 0.28 kΩ HINT:
If the resistance is out of the specified range with the ATF temperature shown in the table above, the driveability of the vehicle may decrease.
If the resistance value is not as specified, replace the transmission wire.
- Measure the resistance according to the value(s) in the table below.