Inspection Procedure
- READ VALUE OF TECHSTREAM (RHEOSTAT VALUE)
- Connect Techstream to the DLC3.
- Ignition switch on (IG).
- Turn the tester on.
- Enter the following menus: Body Electrical / Combination Meter / Active Test.
- Check the values by referring to the table below.
Combination Meter:
DATA LIST - COMBINATION METERTester Display Measurement Item/Range Normal Condition Rheostat value Light control rheostat/Min.: 0%, Max.: 100% Light control rheostat switch is Dark (0%) → Bright (100%) OK:
The value displayed on the tester gradually changes as the actual rheostat operation.
NG: Go to step 5
OK: Go to next step
- CHECK ILLUMINATION
OK
RESULT REFERENCEResult Proceed to All illumination does not change. A Only combination meter illumination does not change. A Lounge illumination / Push start button illumination does not change. B Other illumination (navigation, audio, etc.) does not change. C B: Go to step 3
C: Go to step 4
A : REPLACE COMBINATION METER ASSEMBLY
- REPLACE BODY ECU
HINT:
Check illumination circuit before replacing body ECU (See PROBLEM SYMPTOMS TABLE ).
OK:
Operation of the light control rheostat returns to normal.
NG: REPLACE COMBINATION METER ASSEMBLY
OK : END
- INSPECT COMBINATION METER ASSEMBLY
- Disconnect the E2 connector.
- Measure the voltage according to the value(s) in the table below.
Voltage
VOLTAGE SPECIFICATIONTester Connection Condition Specified Condition E2-11 (ILL) - Body ground Ignition switch on (IG), and TAIL light ON 10 to 14 V E2-11 (ILL) - Body ground Ignition switch off Below 1 V
NG: REPLACE COMBINATION METER ASSEMBLY
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK : CHECK ILLUMINATION
- INSPECT LIGHT CONTROL RHEOSTAT
- Remove the light control rheostat.
- Measure the resistance according to the value(s) in the table below.
Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition E1-1 (E) - E1-4 (RV) Rheostat knob fully turns clockwise. 8 to 12 Ω E1-1 (E) - E1-4 (RV) Rheostat knob fully turns counterclockwise. Approx. 0 Ω E1-2 (TC) - E1-3 (T) Rheostat knob fully turns clockwise. Below 1 Ω E1-2 (TC) - E1-3 (T) Rheostat knob fully turns counterclockwise. 10 kΩ or higher
NG: REPLACE LIGHT CONTROL RHEOSTAT
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT)
- Disconnect the E1 and E2 connectors.
- Measure the resistance according to the value(s) in the table below.
Resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition E1-1 (E) - Body ground Always 10 kΩ or higher E1-2 (TC) - Body ground Always 10 kΩ or higher E1-3 (T) - Body ground Always 10 kΩ or higher E1-4 (RV) - Body ground Always 10 kΩ or higher E1-1 (E) - E2-22 (RE) Always Below 1 Ω E1-2 (TC) - E2-19 (TC SW) Always Below 1 Ω E1-3 (T) - E2-20 (RT) Always Below 1 Ω E1-4 (RV) - E2-21 (RV) Always Below 1 Ω
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK : REPLACE COMBINATION METER ASSEMBLY