LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2008 >> Highlander Base, AWD >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Meter (Except Hybrid) >> Meter/Gauge System >> Entire Combination Meter Does Not Operate >> Inspection Procedure

Inspection Procedure

  1. INSPECT COMBINATION METER ASSEMBLY 
    1. Disconnect the E1 connector.
    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION TABLE

      Tester Connection Condition Specified Condition
      E1-20 (ES) - Body ground Always Below 1 Ω
      E1-40 (E2) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard voltage 

      TESTER CONNECTION SPECIFIED CONDITION TABLE

      Tester Connection Condition Specified Condition
      E1-1 (IG+) - Body ground Ignition switch on (IG) 10 to 14 V
      E1-21 (B) - Body ground Always 10 to 14 V
      E1-22 (B2) - Body ground Always 10 to 14 V
      Fig 1: Identifying E1 Connector
      G05420384Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: REPLACE COMBINATION METER ASSEMBLY  (See REMOVAL  )