Inspection Procedure
HINT:
Read freeze frame data using a Techstream. Freeze frame data record the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data, from the time the malfunction occurred.
- READ VALUE USING TECHSTREAM (STOP LIGHT SWITCH)
- Connect a Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the tester ON.
- Select the following menu items: Powertrain / Engine and ECT / Data List / All Data / Stop Light Switch.
- Read the values displayed on the tester.
Standard
NORMAL CONDITION CHARTItem Measurement Item: Range (display) Normal Condition Stop Light Switch Stop light switch status: ON or OFF - ON: Brake pedal is depressed
- OFF: Brake pedal is released
NG: Go to step 2
OK: CHECK FOR INTERMITTENT PROBLEMS (See CHECK FOR INTERMITTENT PROBLEMS )
- CHECK STOP LIGHT SWITCH INSTALLATION
- Check the stop light switch installation (See REMOVAL
).
OK: Stop light switch is installed correctly.
NG: SECURELY REINSTALL STOP LIGHT SWITCH (See REMOVAL )
OK: Go to Next Step
- Check the stop light switch installation (See REMOVAL
).
- INSPECT STOP LIGHT SWITCH ASSEMBLY (See INSPECTION PROCEDURE
)
NG: REPLACE STOP LIGHT SWITCH ASSEMBLY (See REMOVAL )
OK: Go to Next Step
- CHECK HARNESS AND CONNECTOR (STOP LIGHT SWITCH - ECM)
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Disconnect the A21 ECM connector.
- Disconnect the A13 stop light switch connector.
- Check the resistance.
Standard resistance (Check for open)
TESTER CONNECTIONS SPECIFIED CONDITIONS CHARTTester Connections Specified Conditions STP (A21-36) - Stop light switch (A13-1) Below 1Ω ST1- (A21-35) - Stop light switch (A13-4) Standard resistance (Check for short)
TESTER CONNECTIONS SPECIFIED CONDITIONS CHARTTester Connections Specified Conditions STP (A21-36) or Stop light switch (A13-1) - Body ground 10 kΩ or higher ST1- (A21-35) or Stop light switch (A13-4) - Body ground - Reconnect the ECM connector.
- Reconnect the stop light switch connector.
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE ECM (See REMOVAL )