Inspection Procedure
HINT:
Using Techstream's Data List allows switch, sensor, actuator and other item values to be read without removing any parts. Reading the Data List early in troubleshooting is one way to save time.
- Warm up the engine.
- Turn the ignition switch OFF.
- Connect Techstream to the DLC3.
- Turn the ignition switch ON and turn the tester ON.
- Enter the following menus: Powertrain / Engine and ECT / Data List.
- Follow the instructions on the tester and read the Data List.MEASUREMENT ITEM/RANGE AND DIAGNOSTIC NOTE
Tester Display Measurement Item/Range Normal Condition Diagnostic Note SPD (NT) Input turbine speed/ Min.: 0 rpm
Max.: 12,750 rpm- Lock-up ON (after warming up engine):
Input turbine speed (NT) equal to engine speed.
- Lock-up OFF (idling with shift lever on N):
Input turbine speed (NT) is nearly equal to engine speed.
Data is displayed in increments of 50 rpm HINT:
- SPD (NT) is always 0 rpm while driving:
Open or short in the sensor or circuit.
- SPD (NT) is always more than 0 rpm and less than 300 rpm while driving the vehicle at 50 km/h (31 mph) or more:
Sensor trouble, improper installation, or intermittent connection trouble of the circuit.
- Lock-up ON (after warming up engine):
- INSPECT SPEED SENSOR (INSTALLATION)
- Check the speed sensor NT installation.
OK: Installation bolt is tightened properly and there is no clearance between the sensor and transaxle case.
NG: SECURELY INSTALL SENSOR OR REPLACE SPEED SENSOR
OK: Go to Next Step
- Check the speed sensor NT installation.
- INSPECT SPEED SENSOR NT
- Disconnect the B28 sensor connector from the transaxle.
- Measure the resistance of the sensor.
Standard resistance
TESTER CONNECTION AND SPECIFIED CONDITIONTester Connection Condition Specified Condition 1-2 20°C (68°F) 560 to 680 Ω
NG: REPLACE SPEED SENSOR NT
OK: Go to Next Step
- CHECK WIRE HARNESS (SPEED SENSOR - ECM)
- Disconnect the B30 ECM connector.
- Measure the resistance of the wire harness side connector.
Standard resistance
TESTER CONNECTION AND SPECIFIED CONDITIONTester Connection Condition Specified Condition B30-125 (NT+) - B30-124 (NT-) 20°C (68°F) 560 to 680 Ω B30-125 (NT+) - Body ground 20°C (68°F) 10 kΩ or higher B30-124 (NT-) - Body ground 20°C (68°F) 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS AND CONNECTOR
OK: REPLACE ECM