LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2008 >> FJ Cruiser RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 225 (Air Conditioning) >> ROOM TEMPERATURE SENSOR (for Automatic Air Conditioning System) >> Inspection

ROOM TEMPERATURE SENSOR (for Automatic Air Conditioning System): Inspection

WARNING: This page is about a different car, the 2008 Toyota RAV4. However, it is still accessible from the selected car via links, so may be relevant.
  1. INSPECT ROOM TEMPERATURE SENSOR 
    1. Measure the resistance of the sensor.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Condition Specified Condition
      1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
      1 - 2 15°C (59°F) 2.45 to 2.88 kΩ
      1 - 2 20°C (68°F) 1.95 to 2.30 kΩ
      1 - 2 25°C (77°F) 1.60 to 1.80 kΩ
      1 - 2 30°C (86°F) 1.28 to 1.47 kΩ
      1 - 2 35°C (95°F) 1.00 to 1.22 kΩ
      1 - 2 40°C (104°F) 0.80 to 1.00 kΩ
      1 - 2 45°C (113°F) 0.65 to 0.85 kΩ
      1 - 2 50°C (122°F) 0.50 to 0.70 kΩ
      1 - 2 55°C (131°F) 0.44 to 0.60 kΩ
      1 - 2 60°C (140°F) 0.36 to 0.50 kΩ
      NOTE:
      • Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
      • When measuring the resistance, the sensor temperature must be the same as the ambient temperature.

      HINT:

      As the temperature increases, the resistance decreases (see the graph ).

      If the result is not as specified, replace the room temperature sensor.

      Fig 1: Identifying Room Temperature Sensor Resistance Graph
      G04950734Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002