LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2008 >> FJ Cruiser RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 225 (Air Conditioning) >> AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) >> Data List / Active Test

Data List / Active Test

WARNING: This page is about a different car, the 2008 Toyota RAV4. However, it is still accessible from the selected car via links, so may be relevant.
  1. READ DATA LIST 

    HINT:

    Using Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    1. Connect Techstream to the DLC3.
    2. Turn the ignition switch ON and turn Techstream ON.
    3. Read the Data List by following the prompts on the tester.

      Air conditioner: 

      DATA LIST - AIR CONDITIONER

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Room Temperature Sensor Room temperature sensor / Min.: -6.5°C (20.3°F)
      Max.:57.25°C (135.05°F)
      Actual room temperature is displayed Open circuit: -6.5°C (20.3°F)
      Short circuit: 57.25°C (135.05°F)
      Ambient Temp Sensor Ambient temperature sensor / Min.: -23.3°C (-9.94°F)
      Max.: 65.95°C (150.71°F)
      Actual ambient temperature is displayed Open circuit: -23.3°C (-9.94°F)
      Short circuit: 65.95°C (150.71°F)
      Adjusted Ambient Temp Adjusted ambient temperature / Min.: -30.8°C (-23.44°F)
      Max.: 50.8°C (123.44°F)
      - -
      Evaporator Fin Thermistor Evaporator temperature sensor / Min.:-29.7°C (-21.46°F)
      Max.: 59.55°C (139.19°F)
      Actual evaporator temperature is displayed Open circuit: -29.7°C (-21.46°F)
      Short circuit: 59.55°C (139.19°F)
      Solar Sensor (D side) Driver side solar sensor / Min.: 0, Max.: 255 Driver side temperature increases as brightness increases -
      Solar Sensor (P side) Passenger side solar sensor / Min.: 0, Max.: 255 Passenger side temperature increases as brightness increases -
      Engine Coolant Temp Engine coolant temperature / Min.: 1.3°C (34.34°F)
      Max.:90.55°C (194.99°F)
      Actual engine coolant temperature is displayed after engine warmed up -
      Set Temperature (D side) Driver side set temperature / Min.: 0°C (32°F)
      Max.: 30°C (54°F)
      Driver side actual set temperature is displayed -
      Set Temperature (P side) Passenger side set temperature / Min.: 0°C (32°F)
      Max.: 30°C (54°F)
      Passenger side actual set temperature is displayed -
      Blower Motor Speed Level Blower motor speed level / Min.: 0, Max.: 31 Increases in range between 0 and 31 as blower motor speed increases -
      Regulator Pressure Sensor Regulator pressure sensor / Min.: -0.45668 MPaG
      Max.: 3.29437 MPaG
      Actual regulator pressure is displayed -
      Regulator Control Current Regulator control current / Min.:0A
      Max.: 0.997 A
      Value changes between 0 A and 0.997 A in accordance with compressor and magnetic clutch operation -
      Air Mix Servo Targ Pulse (D) Driver side air mix servo motor target pulse / Min.: 0, Max.: 255 Customized value displayed -
      Air Mix Servo Targ Pulse (P) Passenger side air mix servo motor target pulse / Min.: 0, Max.: 255 Customized value displayed -
      Air Outlet Servo Pulse (D) Air outlet servo motor target / Min.: 0, Max.: 255 Customized value displayed -
      Air Inlet Damper Targ Pulse Air inlet damper target pulse / Min.: 0, Max.: 255 Customized value displayed -
      Shift Set Temperature Shift set temperature / +2 C, +1 C, NORMAL, -1 C, -2 C Customized value displayed -
      Air Inlet Mode Air inlet mode / AUTO, MANUAL Customized value displayed -
      Compressor Mode Compressor mode / AUTO, MANUAL Customized value displayed -
      Compressor/DEF Mode Compressor / DEF Mode / LINK, NORMAL Customized value displayed -
      Evaporator Control Evaporator Control / AUTO, MANUAL Customized value displayed -
      Foot/DEF Auto Mode Foot / DEF auto mode / ON, OFF Customized value displayed -
      Foot/DEF Auto Blow Up Foot / DEF automatic blow up function / ON, OFF Customized value displayed -
      Ambient Temperature Shift Ambient temperature shift / +3C, +2C, +1C, Normal, -1C, -2C, -3C Customized value displayed -
      Number of Trouble Codes Number of trouble codes / Min.: 0, Max.: 255 Number of DTCs displayed -
  2. PERFORM ACTIVE TEST 

    HINT:

    Using Techstream to perform Active Tests allows the relay, actuator, and other items to operate without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Test early in troubleshooting is one way to save diagnostic time. Data List information can be display while performing Active Test.

    1. Connect Techstream to the DLC3.
    2. Turn the ignition switch ON and turn Techstream ON.
    3. Perform the Active Test by following the prompts on the tester.

      Air conditioner: 

      ACTIVE TEST - AIR CONDITIONER

      Tester Display Test Part Control Range Diagnostic Note
      Blower Motor Blower motor Min.: 0, Max.: 31 -
      Magnetic Clutch Relay Magnetic clutch relay OFF, ON Operating sound can be heard
      Defogger Relay (Rear) Defogger relay (Rear) OFF, ON -
      Air Mix Servo Tang Pulse (D) Air mix servo motor pulse (D side) Min.: 0, Max.: 255 -
      Air Mix Servo Tang Pulse (P) Air mix servo motor pulse (P side) Min.: 0, Max.: 255 -
      Air Outlet Servo Pulse (D) Air outlet servo motor pulse Min.: 0, Max.: 255 -
      Air Inlet Damper Targ Pulse Air inlet damper target pulse Min.: 0, Max.: 255 -