Typical Malfunction Thresholds
WARNING: This page is about a different car, the 2008 Toyota RAV4. However, it is still accessible from the selected car via links, so may be relevant.
Either of the following conditions is met: OFF malfunction (A) and (B), or ON malfunctions (A), (B) and (C)
2 detections are necessary per driving cycle:
1st detection: temporary flag ON
2nd detection: pending fault code ON
OFF malfunction (A):
TYPICAL MALFUNCTION THRESHOLDS CHART - OFF MALFUNCTION (A)
| Input (turbine) speed/Intermediate shaft speed | 0.93 to 1.07 |
OFF malfunction (B):
TYPICAL MALFUNCTION THRESHOLDS CHART - OFF MALFUNCTION (B)
| Intermediate shaft speed/Output speed | 1.02 to 1.16 |
ON malfunction (A):
TYPICAL MALFUNCTION THRESHOLDS CHART - ON MALFUNCTION (A)
| Input (turbine) speed/Intermediate shaft speed | 0.93 to 1.07 |
ON malfunction (B):
TYPICAL MALFUNCTION THRESHOLDS CHART - ON MALFUNCTION (B)
| Input (turbine) speed - Intermediate shaft speed | 700 rpm or more |
ON malfunction (C):
TYPICAL MALFUNCTION THRESHOLDS CHART - ON MALFUNCTION (C)
| Input (turbine) speed - Intermediate shaft speed | Less than -500 rpm or 700 rpm or more |