LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2008 >> FJ Cruiser RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 223 (Engine Control System (2GR-FE)) >> SFI System >> DTC P0351 Ignition Coil "A" Primary / Secondary Circuit; DTC P0352 Ignition Coil "B" Primary / Secondary Circuit; DTC P0353 Ignition Coil "C" Primary / Secondary Circuit; DTC P0354 Ignition Coil "D" Primary / Secondary Circuit; DTC P0355 Ignition Coil "E" Primary / Secondary Circuit; DTC P0356 Ignition Coil "F" Primary / Secondary Circuit >> Inspection Procedure

Inspection Procedure

WARNING: This page is about a different car, the 2008 Toyota RAV4. However, it is still accessible from the selected car via links, so may be relevant.

HINT:

Read freeze frame data using Techstream. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

  1. INSPECT IGNITION COIL ASSEMBLY (POWER SOURCE) 
    Fig 1: Identifying Ignition Coil Assembly (Power Source)
    G05184040Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Disconnect the ignition coil with igniter connector.
    2. Measure the resistance.

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION CHART

      Tester Connection Specified Condition
      B56-4 (GND) - Body ground Below 1 Ω
      B42-4 (GND) - Body ground Below 1 Ω
      B55-4 (GND) - Body ground Below 1 Ω
      B41-4 (GND) - Body ground Below 1 Ω
      B49-4 (GND) - Body ground Below 1 Ω
      B39-4 (GND) - Body ground Below 1 Ω
    3. Turn the ignition switch ON.
    4. Measure the voltage between the terminals of the wire harness side connector.

      Standard voltage 

      TESTER CONNECTION SPECIFIED CONDITION CHART

      Tester Connection Specified Condition
      B56-1 (+B) - B56-4 (GND) 9 to 14 V
      B42-1 (+B) - B42-4 (GND) 9 to 14 V
      B55-1 (+B) - B55-4 (GND) 9 to 14 V
      B41-1 (+B) - B41-4 (GND) 9 to 14 V
      B49-1 (+B) - B49-4 (GND) 9 to 14 V
      B39-1 (+B) - B39-4 (GND) 9 to 14 V
    5. Reconnect the ignition coil with igniter connector.

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: Go to next step 

  2. CHECK WIRE HARNESS (IGNITION COIL ASSEMBLY - ECM) 
    Fig 2: Identifying Wire Harness (Ignition Coil Assembly - ECM)
    G05184041Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Disconnect the ignition coil with connector.
    2. Disconnect the B30 ECM connector.
    3. Measure the resistance.

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION CHART

      Tester Connection Specified Condition
      B56-2 (IGF) - B30-106 (IGF1) Below 1 Ω
      B42-2 (IGF) - B30-106 (IGF1) Below 1 Ω
      B55-2 (IGF) - B30-106 (IGF1) Below 1 Ω
      B41-2 (IGF) - B30-106 (IGF1) Below 1 Ω
      B49-2 (IGF) - B30-106 (IGF1) Below 1 Ω
      B39-2 (IGF) - B30-106 (IGF1) Below 1 Ω
      B56-3 (IGT1) - B30-40 (IGT1) Below 1 Ω
      B42-3 (IGT2) - B30-39 (IGT2) Below 1 Ω
      B55-3 (IGT3) - B30-38 (IGT3) Below 1 Ω
      B41-3 (IGT4) - B30-37 (IGT4) Below 1 Ω
      B49-3 (IGT5) - B30-36 (IGT5) Below 1 Ω
      B39-3 (IGT6) - B30-35 (IGT6) Below 1 Ω
      B56-2 (IGF) or B30-106 (IGF1) - Body ground 10 kΩ or higher
      B42-2 (IGF) or B30-106 (IGF1) - Body ground 10 kΩ or higher
      B55-2 (IGF) or B30-106 (IGF1) - Body ground 10 kΩ or higher
      B41-2 (IGF) or B30-106 (IGF1) - Body ground 10 kΩ or higher
      B49-2 (IGF) or B30-106 (IGF1) - Body ground 10 kΩ or higher
      B39-2 (IGF) or B30-106 (IGF1) - Body ground 10 kΩ or higher
      B56-3 (IGT1) or B30-40 (IGT1) - Body ground 10 kΩ or higher
      B42-3 (IGT2) or B30-39 (IGT2) - Body ground 10 kΩ or higher
      B55-3 (IGT3) or B30-38 (IGT3) - Body ground 10 kΩ or higher
      B41-3 (IGT4) or B30-37 (IGT4) - Body ground 10 kΩ or higher
      B49-3 (IGT5) or B30-36 (IGT5) - Body ground 10 kΩ or higher
      B39-3 (IGT6) or B30-35 (IGT6) - Body ground 10 kΩ or higher
    4. Reconnect the ECM connector.
    5. Reconnect the ignition coil with igniter connector.

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: Go to next step 

  3. CHECK WHETHER DTC OUTPUT RECURS (DTC P0351, P0352, P0353, P0354, P0355 OR P0356) 
    1. Connect Techstream to the DLC3.
    2. Turn the ignition switch ON and turn the tester ON.
    3. Clear DTCs (see DTC CHECK / CLEAR  ).
    4. Shuffle arrangement of the ignition coils with igniters (among No. 1 to No. 6 cylinders).
      NOTE: Do not shuffle the connectors.
    5. Perform a simulation test.
    6. Check DTCs displayed on the tester.

      Result 

      RESULT CHART

      Display (DTC Output) Proceed to
      Same DTC output A
      Different ignition coil DTC output B

    B: REPLACE IGNITION COIL ASSEMBLY 

    A: REPLACE ECM