LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2008 >> FJ Cruiser RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 200 (Air Conditioning) >> Ambient Temperature Sensor >> Inspection

Ambient Temperature Sensor: Inspection

WARNING: This page is about a different car, the 2008 Toyota Yaris. However, it is still accessible from the selected car via links, so may be relevant.
  1. INSPECT AMBIENT TEMPERATURE SENSOR 
    1. Measure the resistance.

      Standard resistance 

      TESTER CONNECTION AND SPECIFIED CONDITION

      Tester Connection Condition Specified Condition
      1-2 10°C(50°F) 3.00 to 3.73 kΩ
      1-2 15°C(59°F) 2.45 to 2.88 kΩ
      1-2 20°C (68°F) 1.95 to 2.30 kΩ
      1-2 25°C (77°F) 1.60 to 1.80 kΩ
      1-2 30°C (86°F) 1.28 to 1.47 kΩ
      1-2 35°C (95°F) 1.00 to 1.22 kΩ
      1-2 40°C (104°F) 0.80 to 1.00 kΩ
      1-2 45°C (113°F) 0.65 to 0.85 kΩ
      1-2 50°C (122°F) 0.50 to 0.70 kΩ
      1-2 55°C (131°F) 0.44 to 0.60 kΩ
      NOTE:
      • Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
      • When measuring the resistance, the sensor temperature must be the same as the ambient temperature.

      HINT:

      As the temperature increases, the resistance decreases (see the graph).

      If the result is not as specified, replace the ambient temperature sensor.

      Fig 1: Inspecting Ambient Temperature Sensor
      G04829863Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002