AIR CONDITIONING UNIT (for Sedan): Inspection
WARNING: This page is about a different car, the 2008 Toyota Yaris. However, it is still accessible from the selected car via links, so may be relevant.
- INSPECT NO. 1 COOLER THERMISTOR
- Measure the resistance.
Standard resistance
TESTER CONNECTION AND SPECIFIED CONDITIONTester Connection Condition Specified Condition 1-2 -10°C (14°F) 7.30 to 9.10 kΩ 1-2 -5°C (23°F) 5.65 to 6.95 kΩ 1-2 0°C (32°F) 4.40 to 5.35 kΩ 1-2 5°C(41°F) 3.40 to 4.15 kΩ 1-2 10°C(50°F) 2.70 to 3.25 kΩ 1-2 15°C (59°F) 2.14 to 2.58 kΩ 1-2 20°C (68°F) 1.71 to 2.05 kΩ 1-2 25°C (77°F) 1.38 to 1.64 kΩ 1-2 30°C (86°F) 1.11 to 1.32 kΩ NOTE:- Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
- When measuring the resistance, the temperature of the sensor and the cooler thermistor must be the same.
HINT:
As the temperature increases, the resistance decreases (see the graph).
If the operation is not as specified, replace the cooler thermistor.
- Measure the resistance.