LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2008 >> FJ Cruiser RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 169 (Emission Control System (2AZ-FE)) >> Canister >> Inspection

Section 169 (Emission Control System (2AZ-FE)): Canister: Inspection

WARNING: This page is about a different car, the 2008 Toyota RAV4. However, it is still accessible from the selected car via links, so may be relevant.
  1. INSPECT CANISTER 
    1. Visually check the canister for cracks or damage. If cracks or damage is found, replace the canister.
      Fig 1: Inspecting Canister For Cracks Or Damage
      G04485627Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Check the canister operation.
      1. While holding the purge port closed, blow air 0.39 kPa (4.0 kgf/cm2 , 3 mmHg) into the vent port, and check that air flows from the air inlet port.

        If the result is not as specified, replace the canister.

        Fig 2: Checking Air Flows From Air Inlet Port
        G04485628Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      2. While holding the air inlet port closed, blow air 0.39 kPa (4.0 kgf/cm2 , 3 mmHg) into the vent port, and check that air flows from the purge port.

        If the result is not as specified, replace the canister.

        Fig 3: Checking Air Flows From Purge Port
        G04485629Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      3. While holding the air inlet port closed, apply vacuum 3.43 kPa (35.0 kgf/cm2 , 25.7 mmHg) to the vent port, and check that air is sucked into the purge port.

        If the result is not as specified, replace the canister.

        Fig 4: Checking Air Is Sucked Into Purge Port
        G04485630Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    3. Check the air tightness.
      1. While holding the vent and air inlet ports closed, apply vacuum 3.43 kPa (35.0 kgf/cm2 , 25.7 mmHg) to the purge port, and check that the vacuum is maintained for 1 minute.

        If the result is not as specified, replace the canister.

        Fig 5: Checking Vacuum Is Maintained For 1 Minute
        G04485631Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    4. Check the diaphragm.
      1. Remove the air hose between ports A and B.
      2. While holding the vent, purge and air inlet ports closed, apply vacuum 1.42 kPa (14.5 kgf/cm2 , 10.6 mmHg) to port A, and check that air is not sucked into port B.
        Fig 6: Checking Air Is Not Sucked Into Port B
        G04485632Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      3. While holding the vent, purge and air inlet ports closed, apply vacuum 1.42 kPa (14.5 kgf/cm2 , 10.6 mmHg) to port A, and measure how long it takes for the vacuum to drop.

        Vacuum drop time: 10 seconds or more 

        If the result is not as specified, replace the canister.

        Fig 7: Measuring Vacuum Drop By Apply Vacuum
        G04485633Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    5. Check the leak detection pump.
      1. Check that air flows from port A to port B and C.

        If the result is not as specified, replace the canister.

        Fig 8: Checking Air Flows From Port A To Port B And C
        G04485634Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      2. Connect the positive (+) lead of the battery to terminal 7 and the negative (-) lead to terminal 6.
        Fig 9: Connecting Battery To Terminals 6 & 7
        G04485635Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      3. Check that the valve is closed.

        If the result is not as specified, replace the canister.

      4. Install the canister pump module.