Typical Enabling Conditions

WARNING: This page is about a different car, the 2007 Toyota Land Cruiser. However, it is still accessible from the selected car via links, so may be relevant.

Purge VSV Stuck: 

TYPICAL ENABLING CONDITIONS

Enable conditions of EVAP key-OFF monitor
P043E (Reference orifice - low flow)
P043F (Reference orifice - high flow)
P0441 (Purge VSV - stuck open)
P0441 (Purge VSV - stuck close)
P0451 (Canister pressure sensor - noise)
P0455 (EVAP gross leak)
P0456 (EVAP small leak)
P2401 (Leak detection pump - stuck OFF)
P2402 (Leak detection pump - stuck ON)
P2419 (Vent valve - stuck ON)
P2420 (Vent valve - stuck OFF)
Atmospheric pressure 70 to 110 kPa-a (525 to 825 mmHg-a)
Battery voltage 10.5 V or higher
Vehicle speed 2.5 mph (4 km/h) or less
Ignition switch OFF
Time after key off 5 or 7 or 9.5 hours
Canister pressure sensor malfunction (P0450, P0452, P0453) Not detected
Purge VSV Not operated by scan tool
Vent valve Not operated by scan tool
Leak detection pump Not operated by scan tool
Both of the following conditions 1 and 2 are met before key off -
1. Duration that vehicle has been driven 5 minutes or more
2. EVAP purge operation Performed
ECT 4.4 to 35°C (40 to 95°F)
IAT 4.4 to 35°C (40 to 95°F)
  1. Key-off monitor sequence 1 to 8 
    1. Atmospheric pressure measurement 
      TYPICAL ENABLING CONDITIONS CHART

      Next sequence is run if the following condition is met -
      Atmospheric pressure change Less than 0.3 kPa-g (2.25 mmHg-g) in 1 second
    2. First reference pressure measurement 
      TYPICAL ENABLING CONDITIONS CHART

      Next sequence is run if the following conditions are met -
      EVAP pressure just after reference pressure measurement start -1 kPa-g (-7.5 mmHg-g) or lower
      Reference pressure -4.85 to -1.05 kPa-g (-36.4 to -7.93 mmHg-g)
      Reference pressure Saturated within 60 seconds
    3. Vent valve stuck closed check 
      TYPICAL ENABLING CONDITIONS CHART

      Next sequence is run if the following condition is met -
      EVAP pressure change after vent valve is ON 0.3 kPa-g (2.25 mmHg-g) or more
    4. Vacuum introduction 
      TYPICAL ENABLING CONDITIONS CHART

      Next sequence is run if the following condition is met -
      EVAP pressure Saturated within 15 minutes
    5. Purge VSV stuck closed check 
      TYPICAL ENABLING CONDITIONS CHART

      Next sequence is run if the following condition is met -
      EVAP pressure change after purge valve is open 0.3 kPa-g (2.25 mmHg-g) or more
    6. Second reference pressure measurement 
      TYPICAL ENABLING CONDITIONS CHART

      Next sequence is run if the following conditions are met -
      EVAP pressure just after reference pressure measurement start -1 kPa-g (-7.5 mmHg-g) or lower
      Reference pressure -4.85 to -1.05 kPa-g (-36.4 to -7.93 mmHg-g)
      Reference pressure Saturated within 60 seconds
      Difference between first reference pressure and second reference pressure Less than 0.7 kPa-g (5.25 mmHg-g)
    7. Leak check 
      TYPICAL ENABLING CONDITIONS CHART

      Next sequence is run if the following condition is met -
      EVAP pressure when vacuum introduction is complete Lower than second reference pressure
    8. Atmospheric pressure measurement 
    TYPICAL ENABLING CONDITIONS CHART

    EVAP monitor is complete if the following condition is met -
    Atmospheric pressure difference between sequence 1 and 8 Within 0.3 kPa-g (2.25 mmHg-g)