Inspection Procedure
- CHECK FOR DTC (CENTER AIRBAG SENSOR)
- Turn the ignition switch ON, and wait for at least 60 seconds.
- Clear the DTCs (see DTC CHECK / CLEAR ).
- Turn the ignition switch OFF.
- Turn the ignition switch ON, and wait for at least 60 seconds.
- Check for DTCs (see DTC CHECK / CLEAR ).
OK: DTC B1650/32 is not output.
HINT:
DTCs other than B1650/32 may be output at this time, but they are not related to this check.
OK: USE SIMULATION METHOD TO CHECK
NG: GO to Next Step
- CHECK FOR DTC (OCCUPANT CLASSIFICATION ECU)
- Turn the ignition switch ON, and wait for at least 10 seconds.
- Using the intelligent tester (with CAN VIM), check for DTCs of the occupant classification ECU (see DTC CHECK / CLEAR ).
OK: DTC is not output.
NG: GO TO DTC CHART
OK: GO to Next Step
- CHECK CONNECTION OF CONNECTOR
- Turn the ignition switch OFF.
- Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
- Check that the connectors are properly connected to the center airbag sensor and the occupant classification ECU.
OK: The connectors are properly connected.
NG: CONNECT CONNECTOR
OK: GO to Next Step
- CHECK FLOOR WIRE NO. 2 (OPEN)
- Disconnect the connectors from the center airbag sensor and occupant classification ECU.
- Using a service wire, connect L1-8 (FSR+) and L1-4 (FSR-) of connector C.NOTE: Do not forcibly insert the service wire into the terminals of the connector when connecting.
- Measure the resistance of the wire harness side connector.
Standard resistance
TESTER CONNECTION AND SPECIFIED CONDITIONTester Connection Specified Condition L7-16 (FSP+) - L7-24 (FSP-) Below 1 Ω
NG: REPAIR OR REPLACE FLOOR WIRE NO. 2
OK: GO to Next Step
- CHECK FLOOR WIRE NO. 2 (SHORT)
- Disconnect the service wire from connector C.
- Measure the resistance of the wire harness side connector.
Standard resistance
TESTER CONNECTION AND SPECIFIED CONDITIONTester Connection Specified Condition L7-16 (FSP+) - L7-24 (FSP-) 1 MΩ or higher
NG: REPAIR OR REPLACE FLOOR WIRE NO. 2
OK: GO to Next Step
- CHECK FLOOR WIRE NO. 2 (TO B+)
- Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
- Turn the ignition switch ON.
- Measure the voltage of the wire harness side connector.
Standard voltage
TESTER CONNECTION AND SPECIFIED CONDITIONTester Connection Specified Condition L7-16 (FSP+) - Body ground Below 1 V L7-24 (FSP-) - Body ground Below 1 V
NG: REPAIR OR REPLACE FLOOR WIRE NO. 2
OK: GO to Next Step
- CHECK FLOOR WIRE NO. 2 (TO GROUND)
- Turn the ignition switch OFF.
- Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
- Measure the resistance of the wire harness side connector.
Standard resistance
TESTER CONNECTION AND SPECIFIED CONDITIONTester Connection Specified Condition L7-16 (FSP+) - Body ground 1 MΩ or higher L7-24 (FSP-) - Body ground 1 MΩ or higher
NG: REPAIR OR REPLACE FLOOR WIRE NO. 2
OK: GO to Next Step
- CHECK CENTER AIRBAG SENSOR ASSEMBLY
- Replace the center airbag sensor (see
CENTER AIRBAG SENSOR ASSEMBLY ).
HINT:
Perform the inspection using parts from a normal vehicle when possible.
- Connect the connectors to the center airbag sensor.
- Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
- Turn the ignition switch ON, and wait for at least 60 seconds.
- Clear the DTCs (see DTC CHECK / CLEAR ).
- Turn the ignition switch OFF.
- Turn the ignition switch ON, and wait for at least 60 seconds.
- Check for DTCs (see DTC CHECK / CLEAR ).
OK: DTC B1650/32 is not output.
HINT:
DTCs other than B1650/32 may be output at this time, but they are not related to this check.
OK: USE SIMULATION METHOD TO CHECK
NG: GO to Next Step
- Replace the center airbag sensor (see
CENTER AIRBAG SENSOR ASSEMBLY ).
- REPLACE OCCUPANT CLASSIFICATION ECU
- Turn the ignition switch OFF.
- Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
- Replace the occupant classification ECU (see OCCUPANT CLASSIFICATION ECU ).
- PERFORM ZERO POINT CALIBRATION
- Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
- Turn the ignition switch ON.
- Using the intelligent tester, perform the zero point calibration (see INITIALIZATION ).
OK: COMPLETED is displayed on the tester.
- PERFORM SENSITIVITY CHECK
- Using the intelligent tester, perform the sensitivity check (see
INITIALIZATION ).
Standard value:
27 to 33 kg (59.52 to 72.75 lb)
NEXT: END
- Using the intelligent tester, perform the sensitivity check (see
INITIALIZATION ).