Vanity Light: Inspection
- INSPECT VANITY LIGHT ASSEMBLY
- Measure the voltage according to the value(s) in the table below.
Standard voltage:
LH Side
VOLTAGE SPECIFICATION LHTester Connection Condition Specified Condition Q7-1 - Q7-2 Visor raise Below 1 V Visor lower and mirror cover open 11 to 14 V Visor lower and mirror cover close Below 1 V RH Side
VOLTAGE SPECIFICATION RHTester Connection Condition Specified Condition Q8-1 - Q8-2 Visor raise Below 1 V Visor lower and mirror cover open 11 to 14 V Visor lower and mirror cover close Below 1 V If the result is not as specified, there is a malfunction on the wire harness side.
If the result is as specified, but the vanity light light does not come on, replace the bulb.
- Measure the voltage according to the value(s) in the table below.