Inspection Procedure
- PERFORM ACTIVE TEST BY TECHSTREAM
- Connect Techstream to the DLC3.
- Turn the ignition switch on (IG).
- Turn Techstream on.
- Select the following menu items: Body Electrical / Main Body / Active Test.
- Check that the relay operates.MAIN BODY CONTROL RANGE REFERENCE
Tester Display Test Part Control Range Diagnostic Note Taillight Relay Taillight relay ON/OFF - OK:
Taillight relay operates. (Taillights illuminate.)
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
NG: Go to next step
- INSPECT FUSE (TAIL)
- Remove the TAIL fuse from the instrument panel J/B assembly.
- Measure the resistance of the fuse.
Standard resistance:
Below 1 Ω
NG: REPLACE FUSE
OK: Go to next step
- INSPECT TAILLIGHT RELAY
- Remove the taillight relay from the instrument panel J/B assembly.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
RESISTANCE REFERENCETester Connection Specified Condition 3 - 5 10 kΩ or higher Below 1 Ω (When battery voltage is applied to terminals 1 and 2) 3 - 4 Below 1 Ω 10 kΩ or higher (When battery voltage is applied to terminals 1 and 2)
NG: REPLACE TAILLIGHT RELAY
OK: Go to next step
- INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
- Measure the voltage according to the value(s) in the table below.
Standard voltage
VOLTAGE SPECIFICATIONTester Connection Condition Specified Condition IC-4 - Body ground Light control switch OFF → TAIL Below 1 V → 10 to 14 V IC-5 - Body ground Light control switch OFF → TAIL Below 1 V → 10 to 14 V ID-6 - Body ground Light control switch OFF → TAIL Below 1 V → 10 to 14 V ID-14 - Body ground Light control switch OFF → TAIL Below 1 V → 10 to 14 V IP-8 - Body ground Light control switch OFF → TAIL Below 1 V → 10 to 14 V
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK: REPAIR OR REPLACE HARNESS OR CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - BODY GROUND)
NG: Go to next step
- Measure the voltage according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (BATTERY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Disconnect the IA instrument panel J/B assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard voltage
VOLTAGE SPECIFICATIONTester Connection Condition Specified Condition IA-1 - Body ground Always 10 to 14 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR