Inspection Procedure
- READ VALUE OF TECHSTREAM
- Connect Techstream to the DLC3.
- Turn the ignition switch on (IG).
- Turn Techstream on.
- Select the following menu items: Body Electrical / Main Body / Data List.
- Read the display on Techstream.
Main Body:
DATA LIST REFERENCETester Display Measurement Item/Range Normal Condition Diagnostic Note Illumination Rate Illumination rate information / 0 ms to 99.99 ms Value is output according to ambient light levels - OK:
Normal condition listed above is displayed.
OK: REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
NG: Go to next step
- CHECK VEHICLE CONDITION
Result
RESULT REFERENCEVehicle Condition Proceed to Manual Air Conditioning System A Automatic Air Conditioning System B B: Go to step 6
A: Go to next step
- CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - AUTOMATIC LIGHT CONTROL SENSOR)
- Disconnect the E11 automatic light control sensor connector.
- Disconnect the E6 main body ECU connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
RESISTANCE REFERENCETester Connection Condition Specified Condition E6-18 (CLTE) - E11-6 (CLTE) Always Below 1 Ω E6-19 (CLTS) - E11-4 (CLTS) Always Below 1 Ω E6-20 (CLTB) - E11-3 (CLTB) Always Below 1 Ω E6-18 (CLTE) - Body ground Always 10 kΩ or higher E6-19 (CLTS) - Body ground Always 10 kΩ or higher E6-20 (CLTB) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- INSPECT MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Reconnect the main body ECU connector.
- Measure the voltage and resistance according to the value(s) in the table below.
Standard voltage
VOLTAGE SPECIFICATIONTester Connection Condition Specified Condition E11-3 (CLTB) - E11-6 (CLTE) Ignition switch off Below 1 V Ignition switch on (IG) 10 to 14 V Standard resistance
RESISTANCE REFERENCETester Connection Condition Specified Condition E11-6 (CLTE) - Body ground Always Below 1 Ω
NG: REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
OK: Go to next step
- INSPECT AUTOMATIC LIGHT CONTROL SENSOR
- Reconnect the automatic light control sensor connector.
- Connect an oscilloscope to the automatic light control sensor connector.
- Check the waveform.
OK
WAVEFORM REFERENCETester Connection Tool Setting Condition Specified Condition E11-6 (CLTE) - E11-4 (CLTS) 5 V/DIV., 5 ms./DIV. Ignition switch on (IG), light control switch in AUTO Correct waveform is as shown HINT:
If the ambient light becomes brighter, width A becomes narrower.
NG: REPLACE AUTOMATIC LIGHT CONTROL SENSOR
OK: REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
- CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - AUTOMATIC LIGHT CONTROL SENSOR)
- Disconnect the E11 automatic light control sensor connector.
- Disconnect the E6 main body ECU connector.
Standard resistance
RESISTANCE REFERENCETester Connection Condition Specified Condition E6-18 (CLTE) - E11-3 (CLTE) Always Below 1 Ω E6-19 (CLTS) - E11-5 (CLTS) Always Below 1 Ω E6-20 (CLTB) - E11-6 (CLTB) Always Below 1 Ω E6-18 (CLTE) - Body ground Always 10 kΩ or higher E6-19 (CLTS) - Body ground Always 10 kΩ or higher E6-20 (CLTB) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- INSPECT MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
- Reconnect the main body ECU connector.
- Measure the voltage and resistance according to the value(s) in the table below.
Standard voltage
VOLTAGE SPECIFICATIONTester Connection Condition Specified Condition E11-6 (CLTB) - E11-3 (CLTE) Ignition switch off Below 1 V E11-6 (CLTB) - E11-3 (CLTE) Ignition switch on (IG) 10 to 14 V Standard resistance
RESISTANCE REFERENCETester Connection Condition Specified Condition E11-3 (CLTE) - Body ground Always Below 1 Ω
NG: REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
OK: Go to next step
- INSPECT AUTOMATIC LIGHT CONTROL SENSOR
- Reconnect the automatic light control sensor connector.
- Connect an oscilloscope to the automatic light control sensor connector.
- Check the waveform.
OK
WAVEFORM REFERENCETester Connection Tool Setting Condition Specified Condition E11-3 (CLTE) - E11-5 (CLTS) 5 V/DIV., 5 ms./DIV. Ignition switch on (IG), light control switch in AUTO Correct waveform is as shown in Fig 8 HINT:
If the ambient light becomes brighter, width A becomes narrower.
NG: REPLACE AUTOMATIC LIGHT CONTROL SENSOR
OK: REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY