Inspection Procedure
- INSPECT COMBINATION METER ASSY
- Disconnect C9 connector.
- Measure the resistance according to the value (s) in the table below.
Standard:
TESTER CONNECTION SPECIFIED CONDITIONTester connection Condition Specified Condition C9-2-Body ground Always Below 1 Ω - Measure the voltage according to the value (s) in the table below.
Standard:
TESTER CONNECTION SPECIFIED CONDITIONTester connection Condition Specified Condition C9-4 - Body ground Ignition switch ACC or ON 10 to 14 V C9-5 - Body ground Always 10 to 14 V
- NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
- OK: GO TO NEXT STEP
REPLACE COMBINATION METER ASSY (SEE COMBINATION METER ASSY )