Monitor Result (Mode 06 Data)
WARNING: This page is about a different variant/trim than selected.
MONITOR RESULT (MODE 06 DATA)
| Test ID | Test Item | Test Value | Unit Conversion | Unit | Test Limit |
|---|---|---|---|---|---|
| $02 | EVAP gross leak monitor | Fuel tank pressure change for gross leak detection during EVAP leak check | Multiply by 0.0156 | kPa | Malfunction threshold for vapor leak |
| $02 | EVAP leak (0.02 inch) monitor | Fuel tank pressure change for very small leak detection during EVAP leak check | Multiply by 0.0156 | kPa | Malfunction threshold for vapor leak |
Refer to CHECKING MONITOR STATUS for detailed information on Checking Monitor Status.