Inspection Procedure
- INSPECT DLC3 (TS TERMINAL)
- Turn the ignition switch to the ON position.
- Measure the voltage according to the value(s) in the table below.
Standard:
DLC3 CONNECTOR TERMINALS - VOLTAGE TABLETester Connection Condition Specified Condition D3-12 (Ts) - D3-4 (CG) IG switch ON 10 to 14 V NG: Go to step 3
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - DLC3)
- Check the harness and connector between the skid control ECU and DLC3.
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR (TS CIRCUIT)
OK: CHECK AND REPLACE BRAKE ACTUATOR ASSY (See REPLACEMENT )
- CHECK HARNESS AND CONNECTOR (DLC3 - BODY GROUND)
- Measure the resistance according to the value(s) in the table below.
Standard:
DLC3 - BODY GROUND - RESISTANCE TABLETester Connection Specified Condition D3-4 (CG) - Body ground Below 1 Ω NG: REPAIR OR REPLACE HARNESS OR CONNECTOR (GND CIRCUIT)
OK: Go to next step
- Measure the resistance according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - DLC3)
- Check the harness and connector between the skid control ECU and DLC3.
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR (TC CIRCUIT)
OK: CHECK AND REPLACE BRAKE ACTUATOR ASSY (See REPLACEMENT )