LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2006 >> Avalon XLS >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Meter >> Meter / Gauge System >> Fail-Safe Chart

Fail-Safe Chart

ENGINE COOLANT TEMPERATURE GAUGE: 

ENGINE COOLANT TEMPERATURE GAUGE - FAIL-SAFE CHART

Condition Response Recovery
Engine coolant temperature data is interrupted for 5 seconds. The gauge needle indicates below "C". Engine coolant temperature data is received.

SHIFT INDICATOR: 

SHIFT INDICATOR - FAIL-SAFE CHART

Condition Response Recovery
"P to D" data is interrupted for 3 seconds. All indicator lights go off. Normal data is received.
"S" data is interrupted for 3 seconds. The "S" indicator light goes off. Normal data is received.

GEAR POSITION INDICATOR (1 TO 5): 

GEAR POSITION INDICATOR (1 TO 5) - FAIL-SAFE CHART

Condition Response Recovery
Gear position data is interrupted for 3 seconds seconds or a malfunction signal is received. The indicator light goes off. Normal data is received.

ABS & BRAKE: 

ABS & BRAKE - FAIL-SAFE CHART

Condition Response Recovery
ABS & Brake data is interrupted for 3 seconds. The warning light comes on. Normal data is received.

DOOR: 

DOOR - FAIL-SAFE CHART

Condition Response Recovery
Regular data is interrupted. The data received most recently remains indicated. Normal data is received.

HEAD (*1) / TAIL (*2): 

HEAD (*1) / TAIL (*2) - FAIL-SAFE CHART

Condition Response Recovery
Regular data is interrupted. The data received most recently remains indicated. Normal data is received.

BEAM: 

BEAM - FAIL-SAFE CHART

Condition Response Recovery
Regular data is interrupted. The indicator light goes off. Normal data is received.

KEY: 

KEY - FAIL-SAFE CHART

Condition Response Recovery
Regular data is interrupted. The indicator light goes off. Normal data is received.

MULTI-INFORMATION (INSTANTANEOUS FUEL CONSUMPTION/POSSIBLE RUNNING DISTANCE): 

MULTI-INFORMATION (INSTANTANEOUS FUEL CONSUMPTION/POSSIBLE RUNNING DISTANCE) - FAIL-SAFE CHART

Condition Response Recovery
Cruise information data is interrupted for 60 seconds. The display becomes blank (only measurement units are displayed). Normal data is received.

ILLUMINATION: 

ILLUMINATION - FAIL-SAFE CHART

Condition Response Recovery
The illumination data is interrupted for 10 seconds or abnormal data is received. The display remains in daytime mode. Normal data is received.

*1: U.S.A. only

*2: Except U.S.A.